Hobart 00-412788-00002 Thermocouple 48''
Specifications:
- 1900 Series Heavy Duty Thermocouple 48" Long.20-30 Mv
- Coaxial Thermocouple Threads = 11/32"-32
- Market Forge Skillet Where Applicable
- Southbend Hdg-(36, 36M, 36Re, 48, 48M, 48Re, 60, 60M, 60Re,
- 72, 72M, 72Re)
- Vulcan Hart Heavy Duty Range/Oven Gh3/72, Gh3/72C, Gh3/72S,
- Gh30, Gh30C,
- Gh45, Gh45/72, Gh56, Gh56S, Gh6, Gh60, Gh60/45, Gh60/72,
- Gh6045C, Gh60T, Gh60T/45, Gh60T/72, Gh6C, Gh6S, Gh6T45C,
- Gh72, Gh72/45, Ghm3/72, Ghm30, Ghm30C, Ghm45, Ghm45/72,
- Ghm56, Ghm6, Ghm60, Ghm60/45, Ghm60/72, Ghm60T, Ghm60T/45,
- Ghm60T/72, Ghm72, Ghm72/45
Description
Dimensions:
- Weight: 0.3 lbs
- Length: 3 in
- Height: 1 in
- Width: 2.5 in
HOBART:
00-412788-00004 00-906955-00048 412788-00002 412788-00004 412788-2 412788-4 906955-00048 906955-48 HOB00-412788-00002 HOB00-412788-00004 HOB00-906955-00048 HOB412788-00002 HOB412788-00004 HOB412788-2 HOB412788-4 HOB906955-00048 HOB906955-48
MARKET FORGE:
-10-4758 10-4758 MAR10-4758
SOUTHBEND:
-1182565 1182565 SOU1182565
U-LINE:
VULCAN HART:
-00-412788-00002 -00-412788-00004 -00-906955-00048 00-412788-00004 00-412788-00048 00-906955-00048 412788-00002 412788-00004 412788-00048 412788-2 412788-4 412788-48 906955-00048 906955-48 VH00-412788-00002 VH00-412788-00004 VH00-412788-00048 VH412788-00002 VH412788-00004 VH412788-00048 VH412788-2 VH412788-4 VH412788-48 VH906955-00048
Step1: Switch off gas and electrical supply, then allow the unit to cool completely before servicing.
Step2: Open the access panel and detach the old thermocouple from the control valve and pilot bracket.
Step3: Route the new thermocouple along the original path, keeping it free from sharp bends or pressure points.
Step4: Secure the probe tip in direct pilot flame contact and tighten all connections firmly.
Step5: Restore gas supply, light pilot, and verify stable flame retention and proper shutdown response.
-
What maintenance is required for the Hobart 00-412788-00002 Thermocouple?
Inspect the thermocouple regularly for heat damage, corrosion, or loose connections that can affect millivolt output. Keep the sensing tip clean from grease and carbon buildup to maintain accurate flame detection. Ensure secure mounting and proper alignment with the pilot flame. Replace if readings become unstable or response is delayed to maintain better gas operation.
-
What are common issues with the Hobart 00-412788-00002 Thermocouple?
- Weak or inconsistent millivolt output causing shutdowns.
- Pilot flame not properly detected by sensor tip.
- Corrosion or heat fatigue reducing accuracy.
- Loose or damaged electrical connections.
- Carbon buildup on probe affecting signal strength.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More