The Henny Penny 39216 Blower Motor is a high quality part to be used in warmers such as HM, CM, HS, HMR and tall warmers. It uses 200-240V and 3000 RPM, has a 1-1/16” stack, a 3/16” x 2” shaft, and 12” leads for convenient connection. This blower motor provides a proper circulation of air to control the proper warming conditions positively affecting the quality and homogeneity of the food. Therefore, it is durable, finely designed and ideal for giving consistent performance in commercial foodservice applications with minimal breakdown time.

Dimensions

  • Length: 5.7 In
  • Width: 4.3 In
  • Height: 3.3 In
  • Weight: 2.5 lbs
https://partsfe.com/media/catalog/product/h/e/henny-penny-39216-blower-motor-w-12-leads-1-1-16-stack-3-16-x-2-shaft-71466-2.jpg

Product Notes

  • Blower Motor, 200-240V 3000Rpm, 1-1/16" Stack,
  • 3/16" X 2" Shaft, 12" Leads,
  • Henny Penny Warmer Hm, Cm, Hs, Hmr, Tall Units
HENNY PENNY:
Write Your Own Review
You're reviewing:Henny Penny 39216 Blower Motor W/ 12" Leads & 1-1/16" Stack 3/16" X 2" Shaft
Your Rating
Customer Questions
What maintenance is required for the Henny Penny 39216 Blower Motor?

Regularly inspect the blower motor for dust buildup and debris around the housing and shaft. Ensure the leads are securely connected and undamaged. Lubricate bearings if applicable and check for unusual noise or vibration. Disconnect power before servicing.

What are common issues with the Henny Penny 39216 Blower Motor?

  • Motor overheating during operation.
  • Unusual noise or vibration from the shaft.
  • Failure to start due to wiring or internal faults.
  • Reduced airflow caused by worn components.
  • Intermittent operation from loose electrical connections.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power and allow fryer to cool completely before servicing.

Step2: Remove access panel and disconnect old motor wiring carefully noting connections.

Step3: Detach blower assembly from shaft and mounting brackets using proper tools.

Step4: Align new motor shaft and secure using original hardware and fasteners.

Step5: Reconnect electrical leads as labeled ensuring correct polarity and tight connections.

Step6: Restore power and test for smooth operation and unusual noise or vibration.