Specifications:

  • Hi-Limit,Cut Off Temp 700 Degrees Fahrenheit.
  • Reset Under Cap, 2Ea Terminals
  • Prince Castle Toaster Tx-208Bk
  • Roundup Toaster Vct-1000, Vct-1000Sonic, Vct-20, Vct-20Bk,
  • Vct-20 Deluxe, Vct-20 Deluxe With Heated Base, Vct-200,
  • Vct-2000, Vct-2000 Wide Mouth, Vct-2000Sonic, Vct-2010,
  • Vct-20Cv, Vct-25, Vct-250, Vct-50

Description

The Roundup AJ Antunes 4030332 Hi-Limit Thermostat functions as a safety component that protects appliances from overheating. This safety component operates at 700°F temperature reset under CAP through two terminals to provide dependable temperature control which protects equipment from damage. The hi-limit function of this partautomatically stops the power supply when temperature levels cross safety thresholds making it suitable for industrial and improve cooking needs. The thermostat functions with high efficiency and displays extended service life. The exact temperature regulation capability improves operational security by decreasing breakdowns along with maintenance expenses.

Dimensions:

  • Weight: 0.26 lbs
  • Length: 6.5 in
  • Height: 3 in
  • Width: 2 in

FRANKLIN CHEF:

490407

PRINCE CASTLE:

537-476 537-665 PC537-665

ROUNDUP:

7001339 AJA7001339

Step1: Turn off Thermostat power and unplug unit.

Step2: Allow appliance to cool completely.

Step3: Remove access cap and carefully expose the hi-limit thermostat assembly using proper tools.

Step4: Disconnect both terminals, noting wiring positions before removal to ensure correct reconnection.

Step5: Install new thermostat under cap, secure mounting firmly, and reattach terminals.

Step6: Restore power and test reset to confirm proper safe operations.

  • What maintenance is required for the Roundup - AJ Antunes 4030332 Hi-Limit Thermostat?

    Regularly inspect the thermostat for signs of wear, loose connections, or corrosion on terminals. Ensure proper calibration and verify the reset operation operates correctly. Keep surrounding components clean to prevent overheating. Disconnect power before servicing to avoid electrical hazards.

  • What are common issues with the Roundup - AJ Antunes 4030332 Hi-Limit Thermostat?

    • Failure to reset after tripping.
    • Inaccurate temperature cutoff or inconsistent readings.
    • Loose or damaged terminal connections.
    • Premature tripping under normal conditions.
    • Electrical continuity loss due to internal component failure.