Specifications:

  • Pilot Ignition Module, Factory # 5059A-22,
  • Oem #S Type 5059A-22 Exact As White Rogers Type 5059A-21
  • Vulcan Hart
  • Grill Series: 900A W/Electronic Pilot Option, Gdc.

Description

The White Rodgers 5059A-22 Pilot Ignition Module regulates the ignition timing and ignites the pilot burner while providing a flame signal during operation. It does this by controlling ignition timing, and Protection measures and only allows the heating system to run if a pilot light is sensed. The module is usually installed in the control compartment of compatible gas-fired furnaces, boilers and heating equipment and is connected to the ignition and flame-sensing circuits. It is an electronic control part that controls the pilot ignition and flame checking during the heating cycle.

Dimensions:

  • Weight: 0.4 lbs
  • Length: 2 in
  • Height: 2 in
  • Width: 6.5 in

PRODUCT OVERVIEW:
Serving as an electronic control component within a gas appliance ignition system, the White Rodgers 5059A-22 Pilot Ignition Module coordinates electrical functions associated with pilot ignition. The module forms part of the control arrangement between the appliance's ignition components and its control circuit, allowing ignition-related operations to be managed as part of the equipment's operating sequence. Its role is centered on coordinating the electrical side of pilot ignition rather than directly supplying or controlling the gas itself.

PILOT IGNITION CONTROL:
Controls the electrical functions associated with establishing the pilot ignition condition. The module coordinates signals to the applicable ignition components during the pilot-start portion of the operating sequence. This controlled electrical operation allows the ignition system to progress through its designated pilot-related functions before the appliance proceeds to subsequent burner operation.

IGNITION SYSTEM COORDINATION:
Provides an electrical control interface between ignition components and the appliance control circuit. The module receives and processes applicable control signals, coordinating the operation of connected ignition-related components according to the equipment's control sequence. This role allows separate electrical functions within the ignition system to operate in an organized sequence during appliance operation.

REPLACEMENT GUIDELINES:
Replace the White Rodgers 5059A-22 Pilot Ignition Module when electrical or physical deterioration, control failure, or inconsistent signal processing affects its ability to coordinate the appliance's pilot ignition sequence. Replacement is also appropriate when the module no longer supports the required ignition operation or prevents the appliance from progressing normally through its ignition cycle.

COMMON FAILURE SYMPTOMS:

  • Pilot ignition sequence fails to begin normally.
  • Ignition operation becomes inconsistent.
  • Burner operation does not proceed after the ignition attempt.
  • Applicable control signals are not processed correctly.
  • Appliance startup operation becomes irregular.
  • Visible electrical or physical damage appears on the module.

EQUIPMENT COMPATIBILITY:
Verify the White Rodgers 5059A-22 part number, equipment model, and manufacturer documentation before purchasing to confirm the correct application. The existing pilot ignition module configuration and applicable manufacturer parts information should also be compared to confirm that this module corresponds with the intended gas appliance ignition system.

TECHNICAL SPECIFICATIONS:
Brand: White Rodgers
Part Number: 5059A-22
Component Type: Pilot Ignition Module

  • What is the White Rodgers 5059A-22 used for?

    The White Rodgers 5059A-22 is a pilot ignition module used to coordinate electrical functions within the ignition system of applicable gas appliances.

  • What should be checked before ordering the White Rodgers 5059A-22 pilot ignition module?

    Verify the existing module's part number, appliance model, and ignition-system requirements against the applicable equipment documentation to confirm the correct replacement.

  • What may indicate a problem with the White Rodgers 5059A-22 pilot ignition module?

    If the appliance does not complete its intended ignition sequence, the module may need inspection along with the connected ignition components to identify the cause.

  • What can affect the operation of a pilot ignition module?

    Electrical deterioration, physical damage, or failure to process required control signals can affect the module's intended ignition-control function.

  • Why should the White Rodgers 5059A-22 part number be matched before replacing an ignition module?

    Matching the part number with the existing module and equipment documentation helps confirm that the replacement is intended for the appliance's ignition system.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More