Jackson 66851116848 Dishwasher Rinse Temperature Gauge 5/8" U-Clamp 2" Dial

SKU: 66851116848 1-66851116848 Brand: Availability:
In Stock
(0)

$120.03 Price reduced from $199.45
Save $79.42


Have a Question? +1 (866) 863-0907

Specifications:

  • Temperature Gauge, Size 2" Dia Dial [Range 100-220F]
  • Mount U Clamp W/5/8" Jam Nut, [Cap 48"]
  • Bulb 7/16" X 1-3/4", 1/2" Mpt
  • Nsf Approved
  • Jackson Dishwasher Rinse

Description

The Jackson 66851116848 Dishwasher Rinse Temperature Gauge 5/8" U-Clamp 2" Dial operates on the concept of a thermal expansion system in its internal sensing component, converting heat energy to sensed motion. The warmth of water is displayed instantly in a visual readout as the tip is moved on a two-inch circular interface during the sanitation cycle. The hardware is attached to the plumbing of compatible commercial washing equipment with a 5/8" U-clamp screw, with which it is firmly clamped. This mechanical element will enable the thermal conditions in the rinse manifold to be constantly monitored to maintain operational requirements.

Dimensions:

  • Weight: 0.43 lbs
  • Length: 5 in
  • Height: 2.5 in
  • Width: 2.5 in

Step1: Turn off dishwasher power and water supply to ensure safe installation.

Step2: Locate rinse line and identify suitable U-clamp mounting point.

Step3: Secure gauge probe into rinse line using clamp, ensuring tight seal.

Step4: Mount dial gauge upright for easy reading and avoid steam damage.

Step5: Restore water and power, then test temperature reading during cycle.

  • What maintenance is required for the Jackson 66851116848 Rinse Temperature Gauge?

    Regularly inspect the dishwasher gauge for accurate readings and check for any signs of wear or damage. Clean the dial and connection area to prevent buildup. Ensure the fitting is secure and free from leaks. Periodically verify calibration for consistent performance.

  • What are common issues with the Jackson 66851116848 Rinse Temperature Gauge?

    • Inaccurate temperature readings or fluctuations.
    • Fogging or condensation inside the dial.
    • Loose or leaking connection at the fitting.
    • Dial needle sticking or failing to move.
    • Physical damage to the gauge face or casing.