Ember Glo 844214 1980 Series Snap Fit 36" Thermocouple, 20-30 MV

SKU: 844214 1-844214 Brand: Availability:
In Stock
(0)

$21.18 Price reduced from $27.50
Save $6.32


Have a Question? +1 (866) 863-0907

Specifications:

  • 1980 Series Snap Fit 36" Thermocouple, 20-30 Mv
  • Coaxial Thermocouple Threads = 11/32"-32
  • American Metal Ware Coffee 7416.
  • Ember-Glo Broiler 31, 41.
  • Garland Broiler Where Applicable.
  • Oven Where Applicable.
  • Hickory Rotisserie All Gas Models.
  • Part#164

Description

Thermocouple - 36"

Dimensions:

  • Weight: 0.3 lbs
  • Length: 4 in
  • Height: 0.5 in
  • Width: 5 in

PRODUCT OVERVIEW:
Sensing flame conditions within the gas control system, the Ember Glo 844214 Thermocouple provides a temperature-responsive electrical signal used by applicable 1980 Series equipment. The thermocouple operates as part of the flame-sensing arrangement, allowing the gas control system to recognize the condition of the pilot flame and respond according to the equipment's control sequence. Its snap-fit configuration provides the designated connection arrangement for the thermocouple within the applicable assembly.

FLAME SENSING:
Generates a small electrical signal when heat from the pilot flame reaches its sensing junction. The thermoelectric response changes according to the temperature condition at the sensing end, providing the connected control system with an electrical indication associated with the pilot flame. This sensing function allows the thermocouple to serve as the equipment's flame-condition input.

GAS CONTROL SIGNAL:
Provides the electrical signal used by the connected gas-control arrangement to recognize the pilot flame condition. When the sensing junction remains heated, the thermocouple continues producing its thermoelectric output for the control circuit. This signal supports the equipment's established flame-monitoring sequence and helps the gas-control system respond according to the detected condition.

REPLACEMENT GUIDELINES:
Replace the Ember Glo 844214 Thermocouple when physical damage, deterioration, or loss of the expected flame-sensing response affects the thermocouple's ability to provide the required electrical signal. Replacement should also be considered when the thermocouple response becomes inconsistent or no longer supports the intended pilot-flame monitoring function.

COMMON FAILURE SYMPTOMS:

  • Pilot flame sensing becomes inconsistent.
  • Gas control response is affected by an inadequate thermocouple signal.
  • Burner operation does not continue as expected after pilot ignition.
  • Thermocouple response becomes intermittent.
  • Visible damage or deterioration appears on the thermocouple.

EQUIPMENT COMPATIBILITY:
Before purchasing, compare the 844214 part number, 36" length, snap-fit connection, and 20–30 mV rating with the equipment model and applicable Ember Glo manufacturer documentation. Existing thermocouple information should also be checked against the relevant parts information to confirm that this component corresponds with the intended 1980 Series equipment application.

TECHNICAL SPECIFICATIONS:
Brand: Ember Glo
Part Number: 844214
Component Type: Thermocouple
Length: 36"
Electrical Output: 20–30 mV
Series: 1980

  • What is the Ember Glo 844214 Thermocouple used for?

    The Ember Glo 844214 senses heat from the pilot flame and generates a small electrical signal used by the gas-control system to recognize the flame condition.

  • What should be verified before ordering the Ember Glo 844214 Thermocouple?

    Check the 844214 part number, equipment model, and required connection configuration against the equipment's parts documentation to confirm the correct replacement.

  • What may happen if the Ember Glo 844214 thermocouple does not provide a reliable flame-sensing signal?

    The gas-control system may not recognize the pilot flame condition correctly, potentially affecting the intended pilot and burner operating sequence.

  • When should a thermocouple be replaced?

    A thermocouple should be replaced when it is damaged, deteriorated, or no longer provides the expected flame-sensing signal needed by the gas-control system.

  • Why should the snap-fit connection be checked when replacing the Ember Glo 844214?

    The replacement connection must match the equipment's designated fitting arrangement to ensure the thermocouple can be correctly connected to the assembly.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More