The Ranco A30-3953-000 Ice Machine Bin Thermostat with Bulb Holder used as an temperature controller. The partcontrols ice production through temperature monitoring of the bin while stopping excess filling to guarantee operational efficiency. The exact temperature measurement capability makes the system energy efficient by optimizing the ice-making process and minimizing damage to parts. This partserves the food service and hospitality sectors by providing a continuous ice supply while reducing unnecessary ice production. This dependable control system along with its robust design makes the thermostat an essential component that delivers efficient and cost-effective operations to ice machine systems.

Dimensions

  • Length: 6.125 In
  • Width: 2.875 In
  • Height: 2.5 In
  • Weight: 0.34 lbs
https://partsfe.com/media/catalog/product/r/a/ranco-a30-3953-000-ice-machine-bin-thermostat-w-bulb-holder-16671-2.jpg

Product Notes

  • Ice Machine Bin T'Stat, W/ Bulb Holder
  • And 5/16" Id X 14" Tube.
  • Cap 84", Bulb 1/4" X 4", Qty 2 Tabs 1/4",
  • 2.2" Mount Ctrs
  • Bulb Holder Only Hos3A3903-01, List Price $3.38 (Non-Stock)
  • Hoshizaki Ice Machine Series: Km-1201.
  • 900-Sd, B-500Pf, B-700Pf, Km-900Mrh, Km1300Mah, Kml-600Mah,
  • Urc-12F
More Information
Disable SaleableNo
HOSHIZAKI:
420465-02, 4A0824-02, 4A2879-02, HOS4A2879-02, HOSTB0040, HOSTB0041, TB0040, TB0041
Write Your Own Review
You're reviewing:Ranco A30-3953-000 Ice Machine Bin Thermostat W/Bulb Holder
Your Rating
Customer Questions
What maintenance is required for the Ranco A30-3953-000 Thermostat?

Inspect thermostat probe and wiring for corrosion, dirt, or loose connections. Mount securely and test the operation. Proper maintenance ensures accurate bin temperature monitoring and consistent ice production.

What are the common issues with the Ranco A30-3953-000 Thermostat?

  • Incorrect temperature readings.
  • Loose or corroded sensor connections.
  • Failure to cycle harvest properly.
  • Thermostat stuck open or closed.
  • Ice machine stops prematurely.
  • Probe damage from moisture or ice.
  • Erratic ice production.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Shut off power to the ice machine.

Step2: Remove the access panel covering the old thermostat.

Step3: Disconnect wiring and remove the old thermostat.

Step4: Install the new thermostat in the same orientation.

Step5: Reconnect wiring to the correct terminals.

Step6: Secure the thermostat with screws.

Step7: Replace the panel and restore power.

Step8: Test the ice machine for proper bin temperature.