TRUE 800386 Refrigerator Cold Control W/ Dial & Mounting Screws 14.2 to 24.1 F TEMP 42" Capillary Slot Stem 1/4" Female Push-Ons

Special Price $135.97 Regular Price $209.50
In stock
SKU
800386
The True 800386 Refrigerator Temperature Control Kit 42" CAP regulates and monitors the temperature of the internal cabinets to maintain the same cooling effect. This kit is installed in the refrigerators, and it consists of a control mechanism and a capillary tube that helps to check the set temperature range to ensure safe storage of food. It also helps the efficiency and stability of the temperature of the refrigeration system because it operates consistently.

Dimensions

  • Length: 8 In
  • Width: 5 In
  • Height: 2 In
  • Weight: 0.5 lbs
https://partsfe.com/media/catalog/product/t/r/true-800386-refrigerator-cold-control-w-dial-mounting-screws-14-2-to-24-1-f-temp-42-capillary-slot-stem-1-4-female-push-ons-74601-2.jpg

Product Notes

  • Cold Control, 960640, W/ Dial
  • Temp 14.2 To 24.1, Cap 42"
  • Slot Stem, 2Ea. 1/4" Insulated Female Push-Ons,
  • With Mounting Screws,
  • True
Write Your Own Review
You're reviewing:TRUE 800386 Refrigerator Cold Control W/ Dial & Mounting Screws 14.2 to 24.1 F TEMP 42" Capillary Slot Stem 1/4" Female Push-Ons
Your Rating
Customer Questions
What maintenance is required for the TRUE 800386 Cold Control?

Periodically verify the dial moves smoothly and the capillary stem is properly positioned. Inspect electrical terminals for secure connections. Test the cooler’s temperature response to adjustments and ensure consistent cold performance throughout the unit.

What are common issues with the TRUE 800386 Cold Control?

  • Temperature setting not responding correctly.
  • Cooling cycles inconsistent.
  • Dial sticking or difficult to turn.
  • Electrical terminals losing connection.

What maintenance is required for the TRUE 800386 Cold Control With Dial And Mounting Screws?

Keep the refrigerator cold control clean and free of dust to ensure accurate temperature sensing. Inspect capillary tube and electrical connections regularly for wear or corrosion. Tighten mounting screws and ensure dial operates smoothly without resistance.

What are common issues with the TRUE 800386 Cold Control With Dial And Mounting Screws?

  • Inaccurate temperature regulation.
  • Capillary tube leakage or blockage.
  • Faulty dial or unresponsive control.
  • Loose electrical connections causing intermittent cooling.
  • Temperature drift leading to inconsistent cooling performance.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power at breaker to avoid electric shock before starting.

Step2: Remove access panel and note wiring positions and capillary routing carefully.

Step3: Disconnect old control and gently remove capillary bulb from evaporator coil.

Step4: Mount new control with screws and reconnect push-on terminals.

Step5: Insert capillary into slot stem ensuring proper seating and insulation placement.

Step6: Reassemble panel, restore power, and verify thermostat operation and temperature range.