Manitowoc 2006589 Ice Machine Contactor 120V is an electrical part to controls the power supply to the ice making unit as a switch. The operating part of the machine are fulfilled by using use an electromagnetic coil to open or seal the contacts, and permitting or stopping the flow of electricity. The Improved efficiency and reliability in ice production are provided by this contactor, which makes the unit cycle on and off properly and prevents overheating and resulting damage. Benefits include better energy management, increased equipment durability and lower maintenance costs, which makes commercial ice machines in a restaurant and hospitality.

Dimensions

  • Length: 4.5 In
  • Width: 4 In
  • Height: 3 In
  • Weight: 0.54 lbs
https://partsfe.com/media/catalog/product/m/a/manitowoc-2006589-ice-machine-contactor-120v-37157-2.jpg
Manufacturer Name: Manitowoc
Product Number: 2006589
OEM Part Number: 2006589
Product Description: Contactor - 120V
Similar Models:20-0658-9 - Manitowoc
Dimensions:
Length:4.5in/11.43cm
Width:4in/10.16cm
Height:3in/7.62cm
Weight:0.54lbs/244.94g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from PartsFe!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at 866-863-0907 or contact@partsfe.com

MANITOWOC:
20-0658-9, 2006589, MAN2006589
Write Your Own Review
You're reviewing:Manitowoc 2006589 Ice Machine Contactor 120V
Your Rating
Customer Questions
What maintenance is required for the Manitowoc 2006589 Contactor?

Inspect and tighten electrical connections regularly and ensure the contactor is free from dust and carbon buildup. Proper maintenance ensures reliable switching and prevents overheating or arcing. Always disconnect Ice Machine power before servicing and follow safety procedures during inspection.

What are common issues with the Manitowoc 2006589 Contactor?

  • Contact damage leading to intermittent switching.
  • Coil failure causing failure to engage.
  • Overheating due to loose or corroded terminals.
  • Electrical arcing resulting in inconsistent operation.
  • Voltage fluctuations affecting relay performance.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect ice machine power at breaker for safety.

Step2: Remove access panel of ice machine.

Step3: Label and disconnect existing contactor wiring.

Step4: Mount new contactor onto bracket.

Step5: Reconnect wiring per diagram ensuring tight terminals.