Groen CROWN-5887-1 Liquid Level Control

Special Price $863.26 Regular Price $1,009.66
In stock
SKU
CROWN-5887-1
The Groen CROWN-5887-1 Liquid Level Control is a part that measures and controls the height of the fluid in a boiler or kettle and sends an alarm to the control to adjust it. It operates with sensors or probes. This control is attached to the vessel or control panel, and in such a way that the sensors stick out into the liquid chamber. It is mounted in the structure of the equipment and is linked to the wiring harness and communicates with pumps, valves, or heaters to assist in maintaining the correct level of liquid at work.

Dimensions

  • Length: 5 In
  • Width: 5 In
  • Height: 4 In
  • Weight: 0.64 lbs
https://partsfe.com/media/catalog/product/g/r/groen-crown-5887-1-liquid-level-control-91280-2.jpg
Manufacturer Name: Groen
Product Number: CROWN-5887-1
OEM Part Number: CROWN-5887-1
Product Description: Liquid Level Control
Similar Models:5887-1 - CROWN-STEAM, CROWN-4-LLC1 - Groen, 00-857665 - Hobart, 00-881960 - Hobart, 81960 - Hobart, 857665 - Hobart, 881960 - Hobart, 10-7934 - Market-Forge, 97-5608 - Market-Forge, 97-6945 - Market-Forge
Dimensions:
Length:5in/12.7cm
Width:5in/12.7cm
Height:4in/10.16cm
Weight:0.64lbs/290.3g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from PartsFe!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at 866-863-0907 or contact@partsfe.com

CROWN STEAM:
SOUTHBEND:
WARRICK:
26E8B0
Write Your Own Review
You're reviewing:Groen CROWN-5887-1 Liquid Level Control
Your Rating
Customer Questions
What maintenance is required for the Groen CROWN-5887-1 Liquid Level Control?

Regularly inspect the liquid level control for buildup, corrosion, or wiring damage. Clean probes and connections to ensure accurate readings. Tighten electrical terminals and verify calibration periodically. Always disconnect power before servicing to prevent electrical hazards.

What are common issues with the Groen CROWN-5887-1 Liquid Level Control?

  • Inaccurate liquid level readings.
  • Probe scaling or fouling.
  • Electrical connection failures.
  • Control not triggering properly.
  • Intermittent signal or response issues.
  • Sensor malfunction due to corrosion.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off power and shut off water supply to the equipment.

Step2: Drain the tank to a safe level before starting.

Step3: Remove the existing control and disconnect wiring, noting terminal positions.

Step4: Install the new liquid level control and secure it in place.

Step5: Reconnect wiring as per the original configuration.

Step6: Restore water and power, then test to ensure proper level sensing and operation.