Southbend 1177996 Range Hi-Limit Safety Thermostat 10H11 19"L

Special Price $117.60 Regular Price $124.57
In stock
SKU
1177996
Manufacturer:
The Southbend 1177996 Range High Limit Safety Thermostat is the essential equipment that are used to ensure that kitchen appliances do not overheat. It has an accuracy of 270°F (132°C) and 19-inch capillary length to measure and control temperature, and turn off the heat element if it gets too hot. This does not only improve safety factors for it eliminate the possibilities of fire or damage on certain equipment but also increases the life duration of appliances since thermal stress is eliminated. Useful in professional kitchens, it assures precise temperatures and has to be used for preserving the quality of meals and workplace order.

Dimensions

  • Length: 3 In
  • Width: 3 In
  • Height: 2 In
  • Weight: 0.1 lbs
https://partsfe.com/media/catalog/product/s/o/southbend-1177996-range-hi-limit-safety-thermostat-10h11-19-l-78943-2.jpg

Product Notes

  • Hi-Limit, [ Disc Type - 10H11 ] [ Temp 270F ] [ Cap 19" ]
  • Southbend Steamer R-2, Rs4E
SOUTHBEND:
Write Your Own Review
You're reviewing:Southbend 1177996 Range Hi-Limit Safety Thermostat 10H11 19"L
Your Rating
Customer Questions
What maintenance is required for the Southbend 1177996 Hi-Limit Safety Thermostat?

Inspect and test the range thermostat regularly for proper temperature cutoff and reset operation. Ensure electrical connections are tight and free from corrosion. Periodic cleaning and calibration prevents overheating and maintain safe, consistent operation.

What are common issues with the Southbend 1177996 Hi-Limit Safety Thermostat?

  • False tripping causing unexpected shutdowns.
  • Inaccurate temperature cutoff leading to unsafe operation.
  • Wiring faults or corrosion causing intermittent performance issues.
  • Sensor degradation resulting in delayed response.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off electrical power and gas supply at breaker and valve; allow appliance to cool completely to avoid burns.

Step2: Remove front access panel and locate the hi-limit thermostat assembly on the range control area.

Step3: Label all wires carefully then disconnect terminals to prevent miswiring or damage.

Step4: Unscrew faulty thermostat, mount new thermostat securely, ensuring proper alignment with sensor probe.

Step5: Reconnect wiring, reinstall panel, restore power and gas, then test thermostat operation for safety cutoff.