Manitowoc 7052 Ice Machine Water Level Probe

SKU: 7052 1-7052 Brand: Availability:
In Stock
(3)

$66.28 Price reduced from $105.20
Save $38.92


Have a Question? +1 (866) 863-0907

Description

The Manitowoc 7052 Water Level Probe is an essential part of ice production and machine performance. This ice machine probe monitors the water level so that the ice machine water supply remains the same depth for efficient ice formation. The probe uses advanced level sensing technology to detect fluctuations and provide real time feedback to the ice machine control system to help prevent operational problems such as overflows or low water levels that can affect ice quality. Its ability to extend the durability of your ice machine by preventing the damage that can result from water levels.

Dimensions:

  • Weight: 0.16 lbs

Product Overview:
Monitors water level within the reservoir of compatible commercial ice machines. The Manitowoc 7052 Ice Machine Water Level Probe is an OEM water-sensing component. It detects the water condition at its designated sensing point and provides level information as part of the ice machine’s water-management system. The component applies to Manitowoc commercial ice machine equipment requiring this type of water-level sensing function, with compatibility dependent on the specific equipment model and applicable manufacturer parts documentation.

Water System Operation:
Detects the presence of water through electrical conductivity at the designated sensing point. When water reaches the sensing area, the resulting electrical response provides a signal that the equipment control system can recognize as a water-level condition. This operating principle establishes an electrical indication of water presence at the specified level without relying on a mechanical level-sensing mechanism.

Ice Making Support:
Provides water-level feedback to the control system during the ice-making sequence. The detected water condition supplies input associated with the reservoir level, allowing the control system to coordinate the water-fill portion of the operating cycle according to the sensed condition. This places the probe within the water-management portion of the ice production sequence as a dedicated level-sensing input.

Replacement Guidelines:
Replacement may be appropriate when the Manitowoc 7052 no longer provides reliable water-level detection or produces an inconsistent sensing response. Mineral buildup on the sensing surface, damage to the sensing area, or connection problems can interfere with the expected signal. When selecting a replacement, confirm that Manitowoc part 7052 corresponds to the specific ice machine model and applicable manufacturer parts documentation.

Common Failure Symptoms:

  • Intermittent water-level detection
  • Inconsistent water-level signals during operation
  • Water filling stopping or starting at an unexpected point
  • Irregular ice production associated with incorrect water-level sensing
  • Mineral buildup visible on the sensing surface
  • Unreliable sensing associated with loose or corroded connections

Equipment Compatibility:
The Manitowoc 7052 Ice Machine Water Level Probe is an OEM water-sensing component intended for Manitowoc commercial ice machines requiring this probe configuration. Confirm the existing ice machine configuration, water level probe arrangement, and part number against the applicable manufacturer parts documentation before purchase.

Technical Specifications:
Brand: Manitowoc
Part Number: 7052
Product Type: Water Level Probe
Application: Commercial Ice Machine

Step1: Unplug the ice machine and shut off the water supply before starting.

Step2: Locate the water level probe inside the reservoir.

Step3: Disconnect the probe wiring connection.

Step4: Remove the old probe from its mount.

Step5: Insert the new probe in the same position.

Step6: Reconnect wiring securely.

Step7: Restore water and power supply.

Step8: Verify proper water level sensing operation.

  • What maintenance is required for the Manitowoc 7052 Water Level Probe?

    Regularly clean the ice machine probe with a soft cloth and mild detergent to prevent mineral buildup. Inspect for corrosion or damage, and ensure secure electrical connections. Proper maintenance ensures accurate water level readings and prevents operational errors.

  • What are common issues with the Manitowoc 7052 Water Level Probe?

    • Probe failing to detect water.
    • Delayed ice cycle response.
    • False low water readings.
    • Ice machine stopping mid-cycle.

  • What are the common issues with the Manitowoc 7052 Water Level Probe?

    • Inaccurate water level readings.
    • Mineral buildup is causing sensor blockage.
    • Corrosion or rust on the probe.
    • Loose or damaged electrical connections.

Customer Reviews

5 Based on 3 reviews
5 ★
3
4 ★
0
3 ★
0
2 ★
0
1 ★
0
3 reviews
  • Precise Readings
    Orwynn —

    Durable probe with great efficiency

  • Excellent compatibility
    Richard —

    This water level probe is a perfect fit for my ice machine. It restored my machine's performance to like-new levels.

  • High-Quality Part
    Luis —

    This water level probe with harness is a great investment. It's dependable and has made a significant impact in how my ice machine operates.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More