Delfield 2162691-S Refrigerator Fan Motor 3/16" x 7/8" Shaft CW 120V 0.5A
Specifications:
- Fan Motor, Cw From Shaft Side
- 120V, 3/16" X 7/8" Shaft, .5A, 1/2" Stack,
- 1-7/8" Mt Ctrs, Tabs On Bottom Sides.
- Fan Blade # 28-1295 ( Not Included)
- Delfield 186114-Buc, 186114-Ptb, 18648-Buc, 18648-Ptb,
- 18648Ptb, 18660-Buc, 18660-Ptb, 18672-Buc, 18672-Ptb,
- 18691-Buc, 18691-Ptb, 18699-Buc, 18699-Ptb, 18699Buc,
- 18699Ptb, 225L, 227L, 402, 403, 4048-St, 4048-Uc, 406,
- 406Cp, 407, 4148-St, 4148-Uc, 4427N, 4427N-6, 4427N-9M,
- 4432N, 4432N-12M, 4448N, 4448N-12, 4448N-18M, 4448N-8,
- 4460N, 4460N-12, 4460N-8, 4462N-18M, 4464N, 4464N-12,
- 4464N-12M, 4464N-16, 4464N-24M, 4464N-30M, 4464N-8, 4472N,
- 4472N-12, 4472N-18M, 4472N-24M, 4560N, 6025Xl-G,
- 6025Xl-Gh,7048-S, 9036, 9048, 9060, 9072, Ctb8146-Nb,
- Ctb8160-Nb,6025Xl-Ghr, 6025Xl-S, 6025Xl-Sh, 6025Xl-Shr,
Description
Dimensions:
- Weight: 1.1 lbs
- Length: 5 in
- Height: 4 in
- Width: 5 in
This Part Fits the Following Models
100 modelsThis fan motor is used in commercial refrigeration systems to drive air movement across evaporator components, allowing cold air to circulate evenly inside the cabinet. It operates on a 120V electrical supply with a low amperage draw and features clockwise rotation from the shaft side. The 3/16" x 7/8" shaft connects directly to the fan blade assembly, transferring the rotational force needed for internal airflow. When airflow begins to weaken due to motor wear or failure, temperature zones inside the unit can become uneven, and cooling output may drop. Replacing the motor restores air movement across the refrigeration coil area, allowing the system to return to normal cooling conditions in storage and food preservation environments.
Equipment Compatibility:
Common applications for this Refrigerator Fan Motor include commercial refrigeration units, reach-in coolers, prep tables, and storage cabinets used in foodservice environments where consistent airflow circulation is required for proper cooling. This Fan Motor 2162691-S is compatible with commercial refrigeration equipment from leading brands such as Delfield, Randell, and other refrigeration system manufacturers, where steady air movement across cooling components is required for reliable operation.
Brand Compatibility:
Replaces multiple part numbers across various commercial refrigeration equipment brands, including Delfield, Randell, and other compatible refrigeration system manufacturers. Refer to the “Replaces Parts” section for complete cross-reference details.
Product Specifications:
Manufacturer: Delfield
SKU: 2162691-S
Product Type: Refrigerator Fan Motor
Voltage: 120V
Current Rating: 0.5A
Shaft Size: 3/16" x 7/8"
Rotation: Clockwise from the Shaft Side
Mounting Centers: 1-7/8"
Stack Size: 1/2"
Key Features:
- Drives evaporator fan assemblies to circulate air inside refrigeration units
- Promotes even airflow across cooling components for balanced temperature distribution
- Shaft-driven design transfers motor rotation directly to the fan blade assembly
- Helps support uniform cooling inside refrigerated storage compartments
- Replacement option for worn or non-functioning circulation motors
- Designed for continuous operation in commercial refrigeration environments
Users commonly report improved cooling balance after fan motor replacement.
DELFIELD:
2162691 2162691S 216291-S 216291S DEL2162691 DEL2162691-S DEL2162691S DEL216291-S DEL216291S
RANDELL:
EL MTR0230 ELMTR0230 ELMTR230 ELMTR590 RDEL MTR0230 RDELMTR0230 RDELMTR230 RDELMTR590
Step1: Disconnect power to the refrigerator before servicing.
Step2: Remove access panels to reach the existing fan motor.
Step3: Detach wiring and mounting screws from the old motor.
Step4: Position the new fan motor, secure it, and reconnect wiring.
Step5: Replace panels, restore power, and test fan operation.
-
What maintenance is required for the Delfield 2162691-S Fan Motor?
Keep the motor clean and free from dust or debris to ensure proper airflow. Check the fan blades and shaft for wear or alignment issues. Inspect electrical connections regularly and operate safely to prevent short circuits or overheating.
-
What are common issues with the Delfield 2162691-S Fan Motor?
- Overheating during prolonged use
- Fan blades spinning unevenly
- Electrical surges causing motor trips
- Reduced cooling efficiency in the refrigerator
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More