Vulcan Hart 00-419730-00001 Convection Oven Blower Motor Dual Voltage 1PH 1/6HP 115/208-230V 50/60 Hz

Special Price $433.68 Regular Price $715.53
In stock
SKU
00-419730-00001
The Vulcan Hart 00-419730-00001 Blo‍wer Motor i‌s a dua‍l-voltage single⁠-phase drive un‌it rated at 1/4 H‍P f‍or 115/208⁠–2⁠30V, 50/‍60 Hz operat⁠ion campatable commercial Convec⁠tion Ov‍en equipment. It p‌ow‌ers⁠ the convection‌ airflo‍w syst‍em by driving the blower wheel ins​ide co‍mpatible ovens, ensuring continuous a‌ir circulation during ba⁠king⁠ an⁠d roas⁠ting cycl⁠es.⁠ Installed within t⁠he‌ oven’s rear or side mot​or‍ compartment, it supports ev​e⁠n​ heat distribution and stable chamb⁠er tem‌perat‍ures by mai‌nt⁠aining​ consistent inter⁠nal ai⁠rf‍low. This motor is com​monly‍ used⁠ in​ co‌mmercial kitchens, ​and cook‌ing equipment where convection o‍vens a‍re operated for⁠ high-vo​l‍ume‌, temperatur‍e-sensitive food preparation.

Dimensions

  • Length: 12 In
  • Width: 10.5 In
  • Height: 11 In
  • Weight: 13.15 lbs
https://partsfe.com/media/catalog/product/v/u/vulcan-hart-00-419730-00001-convection-oven-blower-motor-dual-voltage-53186-2.jpg

Product Notes

  • Blower Motor, 1 Speed, (Rpm Variance For 60/50 Hz)
  • 1/4 Hp, 115/208-230 V, 60/50 Hz, 1 Ph, 3.3/1.7 Amp
  • 1725/1425 RPM, 2" X 1/2" Shaft, 48Z Frame.
  • Does Not Come With Brackets, # 26-3997
  • Vulcan
  • Oven Series: Gh W/Convection Oven, 7860 Heavy Duty Range
  • 36Lc, 481Lc, 148Lc, 60Lc, 160Lc, 260Lc, Mg12,
  • Requires 2 Ea Mounting Brackets Order # 26-3997 (Not Incl.)
  • Vulcan Blower Wheel # 26-1471
  • Old Style Pancake Motor 115V Only Is # 68-1025

Functions as an integral part of commercial convection oven air circulation systems, this blower motor drives the blower wheel to move heated air throughout the oven cavity for more even heat distribution during cooking. The motor is rated at 1/4 HP and operates on 115/208-230 volts, 60/50 Hz, single-phase power with a speed of 1725/1425 RPM. Commonly used in convection ovens and heavy-duty range oven bases, it helps maintain consistent airflow that supports heating consistency and efficient cooking performance. A worn or malfunctioning blower motor can result in reduced air circulation, uneven cooking results, or heating issues. Replacing the motor may help restore proper airflow and normal oven operation. Mounting brackets are required and sold separately.

Equipment Compatibility:
Suitable for convection oven air circulation applications, the Vulcan Hart Blower Motor includes compatible convection ovens, range ovens, units, and other commercial cooking equipment. This Blower Motor 00-419730-00001 is compatible with commercial equipment from leading brands such as Vulcan Hart and Hobart, and more, where forced-air circulation is required for proper equipment operation.

Brand Compatibility:
This blower motor replaces multiple part numbers used across compatible equipment models from brands such as Vulcan Hart and Hobart. Complete cross-reference details are provided separately for identification and ordering purposes.

Product Specifications:
SKU: 00-419730-00001
Manufacturer: Vulcan Hart
Product Type: Blower Motor
Motor Power: 1/4 HP
Voltage: 115/208-230 VAC
Frequency: 60/50 Hz
Phase: 1 Phase
Amperage: 3.3/1.7 Amp
Speed: 1725/1425 RPM
Shaft Size: 2" x 1/2"
Frame Size: 48Z
Application: Convection Oven Air Circulation

Key Features:

  • Drives the blower wheel to circulate heated air throughout the oven cavity for proper airflow
  • Provides 1/4 HP motor output for convection oven air movement applications
  • Dual-voltage 115/208-230 VAC operation supports compatible commercial equipment requirements
  • Single-speed motor design with 1725/1425 RPM performance depending on frequency
  • Supports consistent heat distribution to help promote even cooking results
  • Used in commercial convection ovens, oven bases, and related cooking equipment applications

Installation Feedback:

Often mentions more consistent oven airflow after replacement.

VULCAN HART:
00-419730-00001, 00-419730-000G1, 413994-2, 419730-00001, 419730-000G1, 419730-1, 419730-G1, 419730G1, VH00-419730-000G1, VH413994-2, VH419730-000G1, VH419730-G1, VH419730G1
Write Your Own Review
You're reviewing:Vulcan Hart 00-419730-00001 Convection Oven Blower Motor Dual Voltage 1PH 1/6HP 115/208-230V 50/60 Hz
Your Rating
Customer Questions
What maintenance is required for the Vulcan Hart 00-419730-00001 Blower Motor?

Inspect the motor and fan blades regularly for dust, grease, or debris buildup. Ensure all electrical connections are tight and check for signs of wear. Clean components carefully and follow proper safety precautions by disconnecting power before servicing. Proper upkeep maintains consistent airflow and performance.

What are common issues with the Vulcan Hart 00-419730-00001 Blower Motor?

  • Motor failing to start or running inconsistently
  • Unusual vibrations or noise from the fan
  • Reduced convection airflow affects cooking
  • Overheating or electrical issues due to loose connections.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off and unplug the appliance to prevent electrical shock.

Step2: Remove the access panel to expose the existing blower motor.

Step3: Disconnect wiring from the old motor, noting connections for proper reinstallation.

Step4: Unscrew and remove the old blower motor from its mount.

Step5: Install the new dual-voltage motor in the same position and secure it with screws.

Step6: Reconnect wiring exactly as noted.

Step7: Replace the access panel, plug in, and test motor operation.