Imperial 2062 Range Burner Orifice Natural Gas 3/8"-27 X 1/2" #39

Special Price $15.05 Regular Price $25.00
In stock
SKU
2062
The Imperial 2062 Range Burner Orifice Natural Gas 3/8"-27 X 1/2‍" #39 is a metering compo‍nent, that re‍gulates flow through a ca‌librated opening to t‍he assembly and maintains, a fixed aperture size to match the requirements of‌ compat‍ib‌le appliances. It chan‌nels gas at a controlled rate based on orifice sizing ensuring consistent delivery to the head for proper combustion within compatible systems. This controlled passage stabilizes fuel-air mixing before ig‍nition at the ports. It is installed within the assembly positioned inline with the fuel supply line to integrate into commercial cooking equipment and aligns‍, with standard threaded connections.

Dimensions

  • Length: 0.75 In
  • Width: 0.5 In
  • Height: 0.5 In
  • Weight: 0.01 lbs
https://partsfe.com/media/catalog/product/i/m/imperial-2062-brass-hood-orfice-3-8-27-x-1-2-high-x-39-nat-65684-2.jpg

Product Notes

  • Brass Hood Orifice,
  • 3/8"-27 X 1/2" High X #39 (Nat)
  • American Range Armg, Artg
  • Imperial Oven Series: Ir W/Convection Oven.
  • Southbend
  • Star Fryer 215B, 615F

A natural gas hood orifice used in commercial cooking equipment, this component meters gas flow into the burner assembly to produce a correctly rated flame output. The #39 sizing delivers a calibrated gas volume, helping maintain proper combustion balance across compatible burner systems. Its 3/8"-27 threaded design with a 1/2" height allows secure installation in supported commercial range and fryer assemblies. During operation, this brass orifice plays a direct role in maintaining correct gas-to-air mixing inside the burner system. If the orifice becomes blocked, worn, or incorrectly matched, it can result in uneven flame behavior, inefficient heating, or ignition issues. Replacing it helps restore proper gas delivery and return burner operation to normal working conditions in everyday kitchen use.

Equipment Compatibility:
Common applications for this natural gas hood orifice include commercial ranges, convection ovens, and fryer equipment used in foodservice kitchens. This Hood Orifice 2062 is compatible with equipment from leading brands such as American Range, Garland, Imperial, Royal Range, Vulcan Hart, Hobart, and Market Forge, and similar manufacturers, where accurate gas metering and proper burner operation are required for standard performance.

Brand Compatibility:
This hood orifice replaces multiple part numbers used across American Range, Garland, Imperial, Jade Range, Royal Range, Vulcan Hart, Hobart, and Market Forge equipment lines. Complete cross-reference details are provided separately for verification and compatibility reference.

Product Specifications:
Manufacturer: Imperial
SKU: 2062
Product Type: Natural Gas Hood Orifice
Material: Brass
Thread Size: 3/8"-27
Height: 1/2"
Orifice Size: #39 (Natural Gas)
Application: Gas Flow Control in Burner Assemblies
Function: Regulates Gas Output for Proper Combustion and Flame Performance

Key Features:

  • Brass body construction designed to regulate gas flow within commercial burner systems
  • #39 precision orifice opening provides measured gas delivery for proper burner output
  • 3/8"-27 threaded design ensures secure fitment in compatible hood and burner assemblies
  • Supports balanced gas and air mixture to help maintain normal burner flame behavior during operation
  • Replacement component used to address issues such as irregular flame patterns, ignition difficulty, or uneven heating performance
  • Field Technician Note:
  • “Once installed, the gas flow settled properly and the burner stopped showing the uneven flame pattern it had before.”
AMERICAN RANGE:
GARLAND:
GLASS MAID:
IMPERIAL:
MARKET FORGE:
93-5158
ROYAL RANGE:
Write Your Own Review
You're reviewing:Imperial 2062 Range Burner Orifice Natural Gas 3/8"-27 X 1/2" #39
Your Rating
Customer Questions
What is the Best Electric Griddle?

Electric Griddle is an electronic equipment that uses an electric element as its heat source. It has a large cooking surface often made up of nonstick material. Electric Griddle has a surface which you do not find in the regular stovetop cookware. ...

What maintenance is required for the Imperial 2062 Hood Orifice?

Clean the orifice regularly to prevent carbon buildup and ensure consistent gas flow. Inspect for clogging or wear during regular equipment servicing. Proper maintenance improves efficiency, safety, and combustion performance. Always shut off gas supply before handling.

What are common issues with the Imperial 2062 Hood Orifice?

  • Clogging from carbon buildup restricting gas flow.
  • Uneven or weak flame performance.
  • Reduced gas output causing heating inefficiency.
  • Thread wear or damage leading to poor fit.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off the gas supply and electrical power before starting safely.

Step2: Carefully remove hood panel and access burner assembly.

Step3: Unscrew existing orifice carefully using the proper tool.

Step4: Inspect threads for damage or debris before installation step.

Step5: Install new orifice and tighten securely without over-torquing.

Step6: Reassemble hood components securely in reverse order carefully.

Step7: Finally test for gas leaks and ignition operation safely.