Keating 004236 Pressure Regulator Natural Gas 3/4" FPT 3"- 6"WC 1/2 PSI
Specifications:
- Nat Gas, 3/4" Fpt Gas In/Out, 3"- 6" Wc, 1/2 Psi
- 250,000 Btu, Maxitrol Rv48L-66-0001 Preset At Factory To 3.5
- American Range
- Bakers Pride Oven Where Applicable.
- Blodgett Oven Series: 900, 999, 1000, Bcg, Fa, Gzl.
- Garland Griddle Series: Gd, Broiler G-80, Ir
- Groen Kettle Ah/1, Ah/1E
- Imperial Oven Ir,Ihr
- Keating Fryer Bb, Cc & Ts: 18" & Up.
- Southbend Oven Series: 300.
- Griddle Series: Sg Counter Top
- Vulcan Broiler, Grill, Warmer Where Applicable.
- Fryer 7594G, Oven Series 7000
- Range 24L, 36L/Lc, 48L/Lc, 148L/Lc, 60L/Lc/Lcc, 161L/Lc,
- 260L/Lc/Lcc.
Description
Dimensions:
- Weight: 0.8 lbs
- Length: 4.5 in
- Height: 3 in
- Width: 3 in
DORMONT:
DYNAMIC COOKING SYSTEMS:
GARLAND:
1019000 1019003 1019010 1019012 2127502 2127503 228052-13 G01740 GL1019000 GL1019003 GL1019010 GL1019012 GL2127502 GLG01740
GRINDMASTER:
HOBART:
00-408279-00001 00-408279-00009 00-408279-00020 00-408279-00022 00-408279-00024 00-408279-00025 108279-1 108279-20 108279-22 108279-9 19954 20024 408279-00001 408279-00009 408279-00020 408279-00022 408279-00024 408279-00025 408279-1 408279-20 408279-22 408279-24 408279-25 408279-9 719954 720024 720064
IMPERIAL:
1050 IMP1050
JADE RANGE:
LANG:
MAGIKITCH'N:
2701-0028200 270100282 27010028200 37N MK2701-0028200 MK270100282 MK27010028200 MK37N MKRP1011 RP1011
NIECO:
RANDELL:
RDLR-06C RDLR06-3/4
ROYAL RANGE:
SOUTHBEND:
STAR MFG:
STERO:
WEL2J-39007 WEL2J39007
VULCAN HART:
00-408279-00001 00-408279-00009 00-408279-00020 00-408279-00022 00-408279-00024 00-408279-00025 108279-1 108279-20 108279-22 108279-9 19954 20024 408279-00001 408279-00009 408279-00020 408279-00022 408279-00024 408279-00025 408279-1 408279-20 408279-22 408279-24 408279-25 408279-9 719954 720024 720064 844516-8 VH108279-1 VH408279-1 VH408279-20 VH844516-8
Step1: Shut off the gas supply and disconnect appliance power before starting installation.
Step2: Remove the old regulator and clean the pipe threads and fittings.
Step3: Apply gas-approved thread sealant to male threads only.
Step4: Mount the new regulator with the flow arrow pointing toward the appliance.
Step5: Secure all connections firmly while avoiding excessive force.
Step6: Turn the gas supply back on and test all connections with a soap-and-water leak solution.
Step7: Confirm the outlet pressure is within the range before operating equipment.
-
What maintenance is required for the Keating 004236 Pressure Regulator?
Inspect the regulator routinely for leaks and ensure stable gas output pressure. Clean exterior surfaces to prevent grease or dust accumulation that could affect operation. Verify all threaded connections remain secure. Replace internal seals or diaphragm components if pressure becomes inconsistent.
-
What are common issues with the Keating 004236 Pressure Regulator?
- Unstable or drifting gas pressure readings.
- Gas leakage at threaded connections.
- Internal diaphragm wear reducing control accuracy.
- Restricted gas flow from internal blockage.
- Failure to maintain consistent outlet pressure.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More