Blodgett 36506 Oven Thermistor Probe W/ Wire Lead Mark V Xcel Series
Dimensions
- Length: 2 In
- Width: 0.75 In
- Height: 6.25 In
- Weight: 0.25 lbs
Product Notes
- Thermistor Probe W/ Wire Leads
- Blodgett Dfg-100 Xcel, Mark V Xcel Series
Observance of Independence day July 4th we are closed [No shipping's and deliveries ] on 07/03/2026, Orders received after 3.00pm CST on 07/02/2026 will be shipping out on Monday 07/06/2026
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Step1: Disconnect oven power supply at breaker to prevent electric shock.
Step2: Open control panel and locate old thermistor probe assembly inside cabinet.
Step3: Carefully disconnect wire lead connectors from terminal harness.
Step4: Remove mounting bracket or probe from oven cavity area.
Step5: Install new thermistor probe in same position and secure firmly.
Step6: Reconnect wire leads matching original wiring diagram and close the panel.
Step7: Restore power and test temperature response for proper operation.