Montague 1070-7 Flame Sensor Probe

SKU: 1070-7 1-1070-7 Brand: Availability:
In Stock
(0)

$25.83 Price reduced from $36.89
Save $11.06


Have a Question? +1 (866) 863-0907

Specifications:

  • Flame Sensing Probe, 1-1/8" Probe,
  • 1/4" Tab Termial Dtraight
  • Groen Boiler Ngb
  • Braising Pan Chfp, Hfp, Nhfp
  • Kettle Sh, Cah, Dh, Tdh, Ngb, Hfb
  • Pitco Fryer Series 18

Description

The Montague 1070-7 Flame Sensor Probe is a safety system that is installed in compatible commercial gas heating and cooking appliances to detect the presence of flames in the burner. It identifies that there is a stable flame and a signal is sent to the controller or gas valve to indicate that ignition has taken place. The probe is installed close to the burner assembly in the combustion chamber and it sticks into the flame path to effectively sense the combustion during normal operation. It is applied in commercial ranges, ovens and broilers in the kitchen settings.

Dimensions:

  • Weight: 0.1 lbs
  • Length: 0.5 in
  • Height: 3.5 in
  • Width: 0.5 in

ANETS:

P5046626

GROEN:

003328 Z003328

PITCO:

P5046626

Step1: Turn off the gas supply and disconnect electrical power before servicing the braising pan.

Step2: Allow the unit to cool completely and access the burner assembly area.

Step3: Remove the defective flame sensing probe and disconnect the terminal connection.

Step4: Install the new probe in the original mounting position and reconnect the terminal securely.

Step5: Ensure the probe tip is properly aligned with the burner flame path.

Step6: Restore power and gas supply, then test ignition and flame sensing operation safely.

  • What maintenance is required for the Montague 1070-7 Flame Sensing Probe?

    Regularly inspect the probe for carbon buildup or residue that may affect flame detection. Clean the sensing rod gently using a soft abrasive pad if deposits are present. Ensure electrical connections remain tight and free from corrosion. Always disconnect power before servicing.

  • What are common issues with the Montague 1070-7 Flame Sensing Probe?

    • Failure to detect flame, causing ignition lockout.
    • Weak or inconsistent signal to control system.
    • Carbon buildup interfering with sensing capability.
    • Loose or corroded electrical connections.
    • Probe misalignment affecting flame contact.

Customer Reviews

No reviews yet. Be the first to write one!