Manitowoc 000002048 Solenoid Coil 110-120V

SKU: 000002048 1-000002048 Brand: Availability:
In Stock
(0)

$51.23 Price reduced from $52.27
Save $1.04


Have a Question? +1 (866) 863-0907

Specifications:

  • Solenoid Coil, 110-120V, 50/60Hz, 8W, Danfoss
  • Manitowoc Bd0322A, Bd0323W, Bd0422A, Bd0423W, Bd0452A,
  • Bd0453W, Bd0492N, Br0320A, Br0321W, Br0420A, Br0421W,
  • Br0450A, Br0451W, Br0490N, Cvd1075, Cvd1285, Cvd1375,
  • Cvd1475, Cvd1476, Cvd1875, Cvd2075, Cvd675, Cvd685, Cvd875,
  • Cvd885, Ib0622Dc, Ib0624Yc, Ib0822Dc, Ib0824Yc, Ib1022Yc,
  • Ib1024Yc, Jd0202A, Jd0203W, Jd0322A, Jd0323W, Jd0422A,
  • Jd0423W, Jd0452A, Jd0453W, Jd0492N, Jr0200A, Jr0201W,
  • Jr0320A, Jr0321W, Jr0420A, Jr0421W, Jr0450A, Jr0451W,
  • Jr0490N, Jy0204A, Jy0205W, Jy0324A, Jy0325W, Jy0424A,
  • Jy0425W, Jy0454A, Jy0455W, Jy0494N, Pd0522R, Pd0532R,
  • Py0524R, Py0534R, Qd0132A, Qd0133W, Qd0202A, Qd0203W,
  • Qd0212A, Qd0213W, Qd0272A, Qd0273W, Qd0282A, Qd0283W,
  • Qd0322A, Qd0323W, Qd0372A, Qd0372Ap, Qd0373W, Qd0373Wp,
  • Qd0422A, Qd0423W, Qd0452A, Qd0453W, Qd0492N, Qd1072C,

Description

The Manitowoc 000002048 Solenoid Coil 110-120V changes electrical power into a magnetic field that when energized, activates a valve or control mechanism attached to it. On the application of power, the coil forms magnetism that causes an internal plunger to move to permit controlled fluid or mechanical flow. This element is mounted in compatible commercial equipment assemblies in which solenoid-operated controls are necessary. Intended to be used with a power supply of it can be used to provide the same cycle of operation in automated systems. The coil is connected to existing wiring and directly mounted.

Dimensions:

  • Weight: 0.25 lbs
  • Length: 2 in
  • Height: 1.25 in
  • Width: 1.25 in

MANITOWOC:

000005156 2001763 5156 MAN000005156 MAN5156

Step1: Disconnect power and apply lockout/tagout before servicing the ice machine.

Step2: Remove the access panel to reach the water/valve solenoid assembly.

Step3: Label and disconnect electrical connectors from the existing coil.

Step4: Slide off the old coil from the valve stem.

Step5: Install the new solenoid coil in the same orientation until fully seated.

Step6: Reconnect wiring securely, ensuring tight terminal fit.

Step7: Reinstall panel, restore power, and test valve actuation during cycle.

  • What maintenance is required for the Manitowoc 000002048 Solenoid Coil?

    Regularly inspect the solenoid coil for overheating, discoloration, or buzzing during operation, which may indicate electrical pressure. Ensure tight, corrosion-free electrical connections to maintain stable voltage supply. Keep surrounding components clean and dry to prevent moisture damage and ensure accurate valve actuation.

  • What are common issues with the Manitowoc 000002048 Solenoid Coil?

    • Coil burnout due to overheating or voltage spikes.
    • Valve not actuating or sticking intermittently.
    • Electrical connection failure or loose terminals.
    • Excessive buzzing or humming during operation.
    • Coil shorting or open circuit failure.