Cleveland 222231 Steamer Vacuum Breaker 125 PSI 1/2" FPT

Special Price $138.23 Regular Price $292.86
In stock
SKU
222231
The Cleveland 222231 Fill Solenoid Valve regulates the flow of water into the steamer chamber and closes and opens according to electrical signals. It switches on when the steamer needs water, so that it can be filled to the correct amount to ensure that the right amount of steam is present during cooking. This 120V valve has a 1/4" female pipe thread connection so that it can easily be fitted into the water supply line. It is installed within the steamer unit, directly on the water inlet to allow smooth running in the system.

Dimensions

  • Length: 4 In
  • Width: 3.5 In
  • Height: 2.75 In
  • Weight: 1.2 lbs
https://partsfe.com/media/catalog/product/c/l/cleveland-222231-steamer-vacuum-breaker-125-psi-1-2-fpt-78092-2.jpg

Product Notes

  • Parker Solenoid Valve, 120V, 1/4" Fpt
  • Cleveland
CLEVELAND:
222231, CLE222231
Write Your Own Review
You're reviewing:Cleveland 222231 Steamer Vacuum Breaker 125 PSI 1/2" FPT
Your Rating
Customer Questions
What maintenance is required for the Cleveland 222231 Vacuum Breaker?

Clean and inspect the Steamer vacuum breaker regularly for mineral buildup and steam leaks. Check seals and gaskets for wear and replace if damaged. Ensure proper venting and secure connections to maintain safe steam system operation.

What are common issues with the Cleveland 222231 Vacuum Breaker?

  • Steam leakage due to worn or damaged seals.
  • Clogging from mineral scale buildup inside valve system.
  • Pressure loss or inconsistent vacuum breaking performance.
  • Corrosion or a steamer valve sticking causing operational issues.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Shut off steam supply and allow the unit to cool completely before servicing.

Step2: Relieve pressure from the system and remove the old vacuum breaker using the correct wrench.

Step3: Clean the pipe threads and inspect fittings for damage or corrosion before installation.

Step4: Apply approved thread sealant and install the new vacuum breaker securely without overtightening.

Step5: Restore steam supply slowly and inspect for leaks while confirming proper pressure relief operation.