Market Forge 94-5022 Oven Spark Ignition Module
Specifications:
- Honeywell Spark Ignition Module
- Cleveland 24Cga10, Sgl-(30,40)-T
Description
Dimensions:
- Weight: 1.2 lbs
- Length: 5 in
- Height: 2.7 in
- Width: 3.7 in
A.O. SMITH:
9004544205
CROWN STEAM:
HOBART:
VULCAN HART:
Step1: Turn off power and gas supply to the oven.
Step2: Access the control panel and locate the ignition module.
Step3: Disconnect wiring carefully, noting positions.
Step4: Remove mounting screws and take out the old module.
Step5: Install the new ignition module and secure it firmly.
Step6: Reconnect wires correctly.
Step7: Restore power and gas, then test ignition for proper operation.
-
What maintenance is required for the Market Forge 94-5022 Spark Ignition Module?
Inspect the oven ignition wires and electrodes for dirt, grease, or wear. Ensure all connections are secure and clean the module exterior. Always disconnect power before servicing.
-
What are common issues with the Market Forge 94-5022 Spark Ignition Module?
- Module fails to generate sparks.
- Loose or corroded wiring connections.
- Worn or misaligned electrodes.
- Intermittent ignition performance.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More