Vulcan Hart 00-498438-0000A SS Griddle Temperature Control Assembly W/ Pointer Knob & 17°F Offset

Special Price $321.67 Regular Price $603.65
In stock
SKU
00-498438-0000A
The Vulcan Hart 00-498438-0000A SS Griddle Temperature Control Assembly is a solid-state temperature control part. It has pointer for adjusting the temperature of the cooker and fluctuations are within a range of 17°F making consistent and easy cooking. This assembly is convenient for a kitchen, among other places, because users can input the temperatures they want and the heater works independently. Some of these advantages include, enhanced heat control, shorter heat recovery cycles and versatility in handling different food types and hence enhanced meal quality and customer satisfaction in conditions with high turnover.

Dimensions

  • Length: 5 In
  • Width: 5 In
  • Height: 5 In
  • Weight: 0.6 lbs
https://partsfe.com/media/catalog/product/v/u/vulcan-hart-00-498438-0000a-ss-griddle-temperature-control-assembly-w-pointer-knob-17-f-offset-85183-2.jpg

Product Notes

  • Ss Temperature Control Assy,W/Pointer Knob And Temperature
  • Overlay.
  • Range 150° - 450°F W/17°F Offset,
  • Input Voltage 115Vac, Sensor Type "K".
  • Fits Vulcan Hart Models~
  • 24Rrg, 36Rrg, 48Rrg, 60Rrg
More Information
Disable SaleableNo
Write Your Own Review
You're reviewing:Vulcan Hart 00-498438-0000A SS Griddle Temperature Control Assembly W/ Pointer Knob & 17°F Offset
Your Rating
Customer Questions
What maintenance is required for the Vulcan Hart 00-498438-0000A Temperature Control Assembly?

Regularly check the temperature control assembly for accurate readings and proper responsiveness. Clean external components to prevent dust buildup that may affect performance. Inspect wiring connections for looseness or damage. Calibrate periodically to ensure consistent temperature regulation and accurate operation.

What are common issues with the Vulcan Hart 00-498438-0000A Temperature Control Assembly?

  • Inaccurate temperature readings or fluctuations.
  • Failure to maintain set temperature levels.
  • Unresponsive or erratic control adjustments.
  • Electrical connection faults or intermittent operation.
  • Overheating or sudden shutdown during use.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off the gas and power supply to the griddle.

Step2: Remove the control panel to access the assembly.

Step3: Disconnect the wiring and the capillary tube from the old control.

Step4: Remove mounting hardware and take out the unit.

Step5: Install the new control assembly and reconnect components.

Step6: Reassemble panel, restore power/gas, and test temperature control.