Cleveland 101207 Steam Thermostatic Trap 1/4" MPT IN X 1/4" CCT OUT

Special Price $155.84 Regular Price $330.18
In stock
SKU
101207
Cleveland 101207 Thermostatic Trap is efficient in removing condensate from steam systems and enhancing its efficiency in operation. It has a 1/4” MPT inlet and 1/4” CCT outlet and works at a pressure of 0-80 PSI 6 bar. Suitable for application in steamers and boilers like BRE-3, BRE-5, and many other convection steamers this trap is effective in minimizing steam leakage and maintaining the temperature. It cuts energy consumption, increases equipment life, and improves the efficiency of steaming making it suitable for use in kitchens.

Dimensions

  • Length: 3.25 In
  • Width: 2 In
  • Height: 2 In
  • Weight: 0.4 lbs
https://partsfe.com/media/catalog/product/c/l/cleveland-101207-steam-thermostatic-trap-1-4-mpt-in-x-1-4-cct-out-14635-2.jpg

Product Notes

  • Steam Trap, Thermostatic. 1/4" Mpt In X 1/4" Cct Out,
  • 0-80 Psi, 6 Bar,
  • Cleveland
  • Boiler Bre-3, Bre-5.
  • Steamer Convection Steamer: Series: 9-Pcdm/Pcgm/Pcsm/Pcem
  • 24/36-Cgm/Cdm/Cem/Cgm/Csm.
CLEVELAND:
Write Your Own Review
You're reviewing:Cleveland 101207 Steam Thermostatic Trap 1/4" MPT IN X 1/4" CCT OUT
Your Rating
Customer Questions
What maintenance is required for the Cleveland 101207 Steam Thermostatic Trap?

Check for water or steam leaks, clean the trap of scale or sediment, and ensure proper seating in the oven or steamer line. Disconnect the appliance before servicing.

What are common issues with the Cleveland 101207 Steam Thermostatic Trap?

  • Steam leaking around the trap.
  • Water hammer or unusual noises.
  • Sediment causing blockage.
  • Malfunctioning valve not regulating properly.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off supply and allow the appliance to cool.

Step2: Remove the old thermostatic trap, noting pipe connections and orientation.

Step3: Clean the mating surfaces to ensure a proper seal.

Step4: Install the new thermostatic trap in the same orientation as the old one.

Step5: Tighten all connections securely to prevent leaks.

Step6: Restore the supply and test for proper operation.