Scotsman 12-2907-21 Ice Machine Water Inlet Solenoid Valve 120V

Special Price $128.42 Regular Price $274.47
In stock
SKU
12-2907-21
The Scot⁠s‍man 12-2907-21 Water Inlet Solenoid Valve 12​0V component controls water e‍ntry into compatible​ i⁠ce mach‍ine systems th‍ro‌ugh a‌n electric​ally operated val‌ve mechanism. It responds to⁠ signal‌s fr​o‍m‌ the co​ntrol circuit by opening or closing the water flow path during ice production cyc⁠les. The valve is mounted within the water supply assembly a⁠nd conn‍ected to both the electrical system, and inle‍t line for coordinated o​per​ati‍on. Its role within t⁠he equipment supports controlled water distribution, regulated filling processes and stable ice pro‍duction perf‍orman‍ce in commercial food service, and‌ b​everage preparation applications.

Dimensions

  • Weight: 0.136 lbs
https://partsfe.com/media/catalog/product/s/c/scotsman-12-2907-21-ice-machine-water-inlet-solenoid-valve-120v-31740-2.jpg

Controls incoming water flow into commercial ice machines by opening and closing the inlet passage during ice production cycles. The Scotsman 12-2907-21 Water Inlet Solenoid Valve operates on a 120V electrical signal and features a brass valve body with a diaphragm actuated design for controlled water delivery. It has a 3/16" CCT inlet, 3/16" ID barbed hose outlet, and 1/4" OD outlet diameter for the specified water connection arrangement. A faulty valve can cause restricted water flow, continuous filling, or insufficient water supply. Replacing the valve can help restore proper water flow control and consistent ice production.

Equipment Compatibility:
Designed for use with Scotsman DC33 and DCE33 commercial ice machines requiring a 120V water inlet solenoid valve for controlled water supply during ice making cycles.

Product Specifications:
SKU: 12-2907-21
Manufacturer: Scotsman
Product Type: Water Inlet Solenoid Valve
Voltage: 120V
Inlet Connection: 3/16" CCT
Outlet Connection: 3/16" ID Barbed Hose Outlet
Outlet Diameter: 1/4" OD
Additional Feature: Includes Cleanout

Key Features:

  • Controls incoming water flow during ice machine fill cycles.
  • Operates with a 120V electrical signal.
  • Features a brass valve body and diaphragm actuated design.
  • Includes an integrated solenoid coil and valve assembly.
  • Provides the specified inlet and outlet connections for the water supply system.
  • Customer Feedback:
  • Water supply issues during the ice making cycle were resolved after the faulty solenoid valve was replaced, and the machine returned to consistent filling and normal ice production.
Write Your Own Review
You're reviewing:Scotsman 12-2907-21 Ice Machine Water Inlet Solenoid Valve 120V
Your Rating
Customer Questions
What is the Best Electric Griddle?

Electric Griddle is an electronic equipment that uses an electric element as its heat source. It has a large cooking surface often made up of nonstick material. Electric Griddle has a surface which you do not find in the regular stovetop cookware. ...

How often should I clean the water inlet valve, and what's the recommended cleaning process?

Cleaning frequency may vary based on usage and water quality. Generally, it's advisable to clean the water inlet valve regularly using a mild detergent. Refer to the product manual for specific cleaning guidelines.

Can the water inlet valve work with water sources that have varying pressure levels, or does it require a constant pressure source?

Water inlet valves are often designed to work with varying water pressure levels. However, it's recommended to check the product specifications and, if necessary, use water pressure regulators to ensure consistent performance.

Does the water inlet valve require any lubrication or maintenance beyond regular cleaning?

Generally, water inlet valves are designed for minimal maintenance. Lubrication requirements, if any, will be specified in the product manual. Regular cleaning is the primary maintenance task for optimal performance.

What maintenance is required for the Scotsman 12-2907-21 Water Inlet Solenoid Valve?

Regularly inspect the ice machine valve for mineral buildup and debris, and clean the inlet screen. Ensure electrical connections are secure and free from corrosion. Proper maintenance prevents leaks and operational failures, and always follow safety precautions when working with water and electricity.

What are common issues with the Scotsman 12-2907-21 Water Inlet Solenoid Valve?

  • Valve fails to open completely.
  • Inconsistent water flow to the ice machine.
  • Delayed ice production.
  • Electrical coil is failing intermittently.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Begin by shutting off the water supply and disconnecting power to the ice machine.

Step2: Locate the inlet valve and disconnect attached water lines.

Step3: Remove electrical connectors carefully.

Step4: Detach the old solenoid valve from its mount.

Step5: Install the new valve in the same position.

Step6: Reconnect water lines and wiring securely.

Step7: Turn water and power back on, then check for leaks.