Star Mfg Y1668 Fryer LCH Hi-Limit Thermostat W/Manual Reset

Special Price $229.72 Regular Price $324.47
In stock
SKU
Y1668
Manufacturer:
The Star Mfg Y1668 Fryer LCH Hi-Limit Thermostat with Manual Reset is an important safety breaker for unit, which turns off fryer and helps to avoid overheating at 450°F and above. This thermostat has a 5/16” x 3-5/8” nickel bulb and a 60” capillary tube to provide accurate temperature control. It has a manual reset button that increases safety since it demands the user to reset the fryer, which cannot be done while the fryer is still unsafe. Suitable for different models, this thermostat not only enhances working conditions’ safety but also helps to increase the service life of fryers and protect them from overheating.

Dimensions

  • Length: 24 In
  • Width: 2.5 In
  • Height: 2 In
  • Weight: 0.78 lbs
https://partsfe.com/media/catalog/product/s/t/star-mfg-y1668-fryer-lch-hi-limit-thermostat-w-manual-reset-36566.jpg

Product Notes

  • [ Type - Lc W/Manual Reset ] [ Temp 450 ]
  • [ Bulb 5/16" X 3-5/8" ] [ Cap 36" ]
  • Star Fryer:
  • 116C, 215B, 216, 404, 510F, 530F, 530T, 530Te, 515, 515E.
Write Your Own Review
You're reviewing:Star Mfg Y1668 Fryer LCH Hi-Limit Thermostat W/Manual Reset
Your Rating
Customer Questions
What maintenance is required for the Star Mfg Y1668 Hi‑Limit Thermostat?

Periodically check the fryer hi‑limit thermostat for dust, grease, or debris buildup and clean gently with a soft brush when power is off. Inspect electrical connections for tightness and corrosion. Test the thermostat’s response regularly to ensure it trips at the correct temperature.

What are the common issues with the Star Mfg Y1668 Hi‑Limit Thermostat?

  • Fails to trip at the set temperature.
  • Erratic or intermittent cutoff behavior.
  • Loose or corroded electrical connections.
  • Sensor drift due to buildup or vibration.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off and unplug the fryer, allowing it to cool completely.

Step2: Remove the existing hi-limit thermostat from the fryer housing.

Step3: Connect the wiring to the matching terminal positions.

Step4: Mount the thermostat securely in place using screws or clips.

Step5: Close any access panels before restoring power.

Step6: Test the fryer carefully, to confirm accurate temperature regulation.