Manitowoc 20-0802-9 Ice Thickness Control Probe, 5-1/2" X 3-1/4"

SKU: 20-0802-9 1-20-0802-9 Brand: Availability:
In Stock
(0)

$96.02 Price reduced from $180.83
Save $84.81


Have a Question? +1 (866) 863-0907

Specifications:

  • Ice Thickness Control Probe, 5-1/2" X 3-1/4" Overall
  • Manitowoc Cvd685, Cvd885, Sd0302A, Sd0303W, Sd0322A,
  • Sd0323W, Sd0422A, Sd0423W, Sd0452A, Sd0453W, Sd0502A,
  • Sd0503W, Sd0592N, Sd0602A, Sd0603W, Sd0603Wm, Sd0692N,
  • Sd0852A, Sd0853W, Sd0853Wm, Sd0892N, Sd1002A, Sd1003W,
  • Sd1003Wm, Sd1072C, Sd1092N, Sd1202A, Sd1203W, Sd1272C,
  • Sd1402A, Sd1403W, Sd1403Wm, Sd1492N, Sd1602A, Sd1603W,
  • Sd1603Wm, Sd1692N, Sd1802A, Sd1803W, Sd1803Wm, Sd1892N,
  • Sd672C, Sd872C, Sr0300A, Sr0301W, Sr0320A, Sr0321W, Sr0420A,
  • Sr0421W, Sr0450A, Sr0451W, Sr0500A, Sr0501W, Sr0590N,
  • Sr0850A, Sr0851W, Sr0851Wm, Sr0890N, Sr1600A, Sr1601W,
  • Sr1601Wm, Sr1690N, Sr1800A, Sr1801W, Sr1801Wm, Sr1890N,
  • Sr870C, Sy0304A, Sy0305W, Sy0324A, Sy0325W, Sy0424A,
  • Sy0425W, Sy0454A, Sy0455W, Sy0504A, Sy0505W, Sy0594N,
  • Sy0604A, Sy0605W, Sy0605Wm, Sy0694N, Sy0854A, Sy0855W,

Description

The Manitowoc 20-0802-9 Ice Thickness Control Probe detects the ice formation by contact or temperature variations as ice forms on the evaporator surface. Once the ice has attained a specified thickness, probe will provide a signal to the control system to start the next phase of the ice-making process. This ice thickness control probe is attached to the evaporator assembly, and the sensing tip is placed so that it is in the ice growth area. It is 5-1/2" by 3-1/4" and has connection wiring.

Dimensions:

  • Weight: 0.14 lbs
  • Length: 6 in
  • Height: 1 in
  • Width: 3.75 in

MANITOWOC:

200802 2008029 MAN20-0802-9 MAN2008029

Step1: Disconnect power and water supply to the ice machine before servicing components.

Step2: Locate the existing thickness probe near the evaporator plate inside the cabinet.

Step3: Carefully disconnect wiring harness and loosen mounting hardware holding the old probe.

Step4: Position the new probe in the same orientation and secure with screws.

Step5: Reconnect wiring firmly, ensuring connections are dry, tight, and properly insulated.

Step6: Restore power, run a cycle, and verify correct ice thickness operation.

  • What maintenance is required for the Manitowoc 20-0802-9 Control Probe?

    Inspect the probe tip regularly for mineral scale and ice buildup and clean it using a soft cloth. Ensure wiring connections remain tight and corrosion-free. Check alignment within the ice bin and confirm accurate sensing response.

  • What are common issues with the Manitowoc 20-0802-9 Control Probe?

    • Inaccurate ice thickness readings due to buildup or residue.
    • Corroded or loose wiring connections causing intermittent signal loss.
    • Misalignment leading to improper ice harvest timing.
    • Sensor failure or erratic operation.