Duke 216516 Refrigerator Evaporator Coil R-134A

SKU: 216516 1-216516 Brand: Availability:
In Stock
(0)

$193.52 Price reduced from $246.95
Save $53.43


Have a Question? +1 (866) 863-0907

Specifications:

  • Duke~
  • 216516 Evaperator Coil
  • Approximaly, L = 15 3/4". W = 6", H = 2"
  • Fits Model Ruf-48

Description

The Duke 216516 Refrigerator Evaporator Coil absorbs heat from circulating air as refrigerant moves through the interconnected tubing inside the cooling circuit. It contains a series of internal passages where heat exchange takes place before the refrigerant advances toward the next section of the sealed structure. Designed for commercial refrigeration systems, the coil is configured for applications using R-134A refrigerant. Following the heat exchange process, the coolant leaves the assembly in a changed condition, continuing its path through the remaining sections of the refrigeration circuit.

Dimensions:

  • Weight: 4.7 lbs
  • Length: 1 in
  • Height: 1 in
  • Width: 1 in

PRODUCT OVERVIEW:
Absorbing heat from the refrigerated compartment, the Duke 216516 Evaporator Coil R-134A functions as a key cooling component within the refrigeration system. The coil allows R-134A refrigerant to circulate through its internal passages, supporting heat exchange between the cabinet air and the refrigerant during the cooling cycle. This OEM evaporator coil provides the heat-transfer surface within the refrigeration assembly, allowing heat from the refrigerated compartment to be absorbed by the refrigerant as part of the cooling process.

HEAT ABSORPTION FUNCTION:
During the refrigeration process, the evaporator coil absorbs heat from the refrigerated compartment as refrigerant passes through its internal tubing during operation. This heat transfer process allows the refrigerant to capture thermal energy from the surrounding air, supporting the cooling process required to maintain the desired storage environment.

REFRIGERANT EVAPORATION PROCESS:
As low-pressure refrigerant flows through the evaporator coil, it absorbs heat from the surrounding refrigerated space and undergoes evaporation within the coil. This phase change allows the refrigerant to capture thermal energy from the compartment before continuing through the refrigeration circuit.

REPLACEMENT GUIDELINES:
Replacement of the Duke 216516 Evaporator Coil R-134A is necessary when coil damage, corrosion, or refrigerant leakage affects its ability to support the refrigeration cooling process. Inspect the coil for visible deterioration or damage that may interfere with refrigerant circulation and heat transfer. A qualified refrigeration technician can assess the coil's condition and determine whether replacement is required to restore its intended cooling function.

COMMON FAILURE SYMPTOMS:

  • Refrigeration compartment does not maintain the required cooling level
  • Uneven frost buildup appears across the coil surface
  • Refrigerant leakage is detected near the coil area
  • Cooling cycle becomes inconsistent
  • Coil shows visible corrosion or physical damage

EQUIPMENT COMPATIBILITY:
The Duke 216516 Refrigerator Evaporator Coil is intended for refrigeration systems that specify an R-134A refrigerant configuration and the corresponding evaporator design. This OEM coil provides the heat-transfer surface where refrigerant absorbs thermal energy from the refrigerated compartment during the cooling cycle. Before replacement, verify the complete equipment model, existing coil configuration, refrigerant specification, and applicable Duke parts documentation to confirm compatibility with the intended refrigeration system.

TECHNICAL SPECIFICATIONS:
Brand: Duke
Part Number: 216516
Component Type: Refrigerator Evaporator Coil
Refrigerant: R-134A

DUKE:

6516-2 DUK216516

  • How does the Duke 216516 Evaporator Coil support the refrigeration process?

    It absorbs heat from the refrigerated compartment as R-134A refrigerant circulates through its internal tubing, supporting heat exchange and cabinet cooling.

  • What refrigeration systems are compatible with the Duke 216516 evaporator coil?

    It is intended for systems designed for R-134A refrigerant and the corresponding evaporator configuration. Verify the complete equipment model and Duke parts documentation before ordering.

  • What symptoms may indicate that the Duke 216516 evaporator coil needs replacement?

    Poor cooling, uneven frost buildup, refrigerant leakage, inconsistent cooling cycles, or visible coil corrosion and damage may indicate an evaporator problem.

  • Why is refrigerant evaporation important in the Duke 216516 coil?

    As low-pressure refrigerant absorbs heat inside the coil, it evaporates and captures thermal energy from the refrigerated compartment before continuing through the refrigeration circuit.

  • What should a technician verify before replacing the Duke 216516 evaporator coil?

    A qualified refrigeration technician should confirm the equipment model, R-134A refrigerant specification, existing coil configuration, and system requirements. The technician should also inspect for leaks, corrosion, and physical damage before replacement.