Manitowoc 000007337 Ice Machine Bin Switch

Special Price $78.14 Regular Price $111.95
In stock
SKU
000007337
The Manitowoc 000007337 Ice Machine Bin Switch is an essential control element intended for controlling the level of ice in the bin. It uses a magnetic reed switch to ascertain when the bin is full, to stop the making of ice so that it does not overflow. This functionality has the effect of increasing effectiveness since the ice machine will only work when necessary through the help of the suggested electric eye. Especially suitable for use in restaurants, this switch not only solves the problem of ice spillage but also ensures the best conditions for ice production, which makes it necessary to install it on any ice machine.

Dimensions

  • Length: 3.5 In
  • Width: 3.5 In
  • Height: 1 In
  • Weight: 0.1 lbs
https://partsfe.com/media/catalog/product/m/a/manitowoc-000007337-ice-machine-bin-switch-71445-2.jpg
Manufacturer Name: Manitowoc
Product Number: 000007337
OEM Part Number: 000007337
Product Description: Bin Switch
Similar Models:7337 - Manitowoc
Dimensions:
Length:3.5in/8.89cm
Width:3.5in/8.89cm
Height:1in/2.54cm
Weight:0.1lbs/45.36g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from PartsFe!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at 866-863-0907 or contact@partsfe.com

MANITOWOC:
000007337, 7337, MAN000007337, MAN7337
Write Your Own Review
You're reviewing:Manitowoc 000007337 Ice Machine Bin Switch
Your Rating
Customer Questions
What maintenance is required for the Manitowoc 000007337 Bin Switch?

Inspect the ice Machine bin switch regularly for ice buildup and debris. Clean contacts and surrounding area to ensure proper signal operation. Proper maintenance helps prevent machine shutdowns and ensures accurate ice level detection and safe operation.

What are common issues with the Manitowoc 000007337 Bin Switch?

  • Ice buildup prevents switch activation
  • Faulty wiring causes intermittent bin signal
  • Misalignment leads to false full/empty readings
  • Switch wear results in inconsistent ice level detection
  • Corrosion on contacts reduces conductivity

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect ice machine power supply to prevent electrical shock.

Step2: Remove outer panel and locate bin switch assembly.

Step3: Disconnect wiring harness carefully noting connections and terminal positions.

Step4: Remove old switch and mount new switch securely in original bracket.

Step5: Reconnect wiring, reassemble panel, restore power, and test operation for proper bin sensing.