Pitco P5047540 Fryer Thermocouple 24"L 20-30mV 1900 Series HD

Special Price $25.98 Regular Price $33.75
In stock
SKU
P5047540
Manufacturer:
The Pitco P5047540 Fryer Ther⁠mocouple 1900 Seri​es HD i‍s a tem‍pe​r​ature sensing co⁠mponent used to monitor heat levels in commercial appliances. The th‌ermocoup​le works‌ by generat⁠ing a small electrical signal when exposed to heat, a​llowing the fryer control system to detect bur​ner f⁠lame presence, and maintain pr‌oper​ temp‌erature reg​ulat​ion. Its 24" le‍ngth pr‌ovides fl​e⁠xibilit‌y for in‌s​tall‌ation w​ithin compatible fryer⁠ as​semblies while sup‍porting stab​le electr‌ical perfor​mance between 20 and 30 millivolts​. T‍his compon⁠ent is⁠ essential for maintaining consistent heating, pre⁠venting‌ unsaf⁠e gas fl‌ow conditions,​ and suppo⁠rting proper fryer operation in restaurants and commercia‌l kitc‌hens.

Dimensions

  • Length: 4.25 In
  • Width: 1 In
  • Height: 1 In
  • Weight: 0.1 lbs
https://partsfe.com/media/catalog/product/p/i/pitco-p5047540-1900-series-hd-thermocouple-24-l-20-30-mv-69157.jpg

Product Notes

  • 1900 Series Heavy Duty Thermocouple 24" Long. 20-30 Mv
  • Coaxial Thermocouple Threads = 11/32"-32
  • Anets
  • Fryer Where Applicable
  • Cecilware
  • Fryer Gf(8,16,28), Fm28

A fryer thermocouple designed for gas cooking equipment that converts heat into a small millivolt signal in the 20–30mV range. The 24-inch probe is placed near the burner area to send temperature feedback to the control system through a threaded 11/32"-32 connection. This signal is part of the ignition and safety process in commercial fryer units. This sensor is commonly used in restaurant fryers and other gas cooking equipment. When the original thermocouple becomes weak or fails, ignition may become unstable or burner operation may stop working properly. Replacing the part brings back normal signal output, so fryer operation returns to basic working condition in busy kitchen environments.

Equipment Compatibility:
Common applications for this Pitco thermocouple include commercial fryers and gas cooking equipment used in foodservice kitchens. This Thermocouple P5047540 is compatible with commercial equipment from leading brands such as Pitco, Vulcan Hart, Frymaster, Hobart, Cecilware, and more, where flame sensing and temperature signal functions are required for operation.

Brand Compatibility:
Replaces multiple part numbers used across various commercial kitchen equipment brands, including Pitco, Vulcan Hart, Frymaster, Hobart, Cecilware, and more. Refer to the “Replaces Parts” section for complete cross-reference details.

Product Specifications:
Product Type: Fryer Thermocouple
Manufacturer: Pitco
SKU: P5047540
Length: 24"
Output: 20–30mV
Thread Type: 11/32"-32
Application: Fryer temperature sensing part
Equipment Type: Commercial fryer component

Key Features:

  • 24" thermocouple probe for fryer systems
  • Produces a 20–30mV signal for the control circuit
  • Threaded connection for basic installation
  • Works with gas fryer burner assemblies
  • Used in commercial kitchen fryer equipment
  • Replacement part for worn or failed sensors
  • Supports normal burner operation after installation

User Feedback:

Many users report smoother burner startup and improved signal response after installing the replacement probe assembly.

Write Your Own Review
You're reviewing:Pitco P5047540 Fryer Thermocouple 24"L 20-30mV 1900 Series HD
Your Rating
Customer Questions
What maintenance is required for the Pitco P5047540 1900 Thermocouple?

Regularly inspect the thermocouple for corrosion, dirt, or loose connections that could affect accurate temperature sensing. Clean gently with a soft cloth if needed. Ensure proper seating in the burner assembly and always disconnect power or gas supply before handling.

What are common issues with the Pitco P5047540 1900 Thermocouple?

  • Incorrect temperature readings or fluctuations.
  • Failure to detect flame, causing safety shutoff.
  • Corrosion or buildup on the sensing tip.
  • Loose or damaged connections affecting performance.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Shut off the gas and allow the appliance to cool.

Step2: Locate the thermocouple at the pilot assembly.

Step3: Disconnect it from the gas valve and bracket.

Step4: Install the new thermocouple in position.

Step5: Tighten connections carefully.

Step6: Restore gas and test pilot flame response for proper operation.