Manitowoc 7601603 Ice Machine Thickness Probe Assembly 14" Lead
Specifications:
- Ice Thickness Probe
- Manitowoc Q Undercounter, Q45,130,210,270
- Qd0132A, Qd0133W, Qd0212A, Qd0213W, Qd0272A, Qd0273W,
- Qm45A,Qm45Ae, Qr0130A, Qr0131W, Qr0210A, Qr0211W, Qr0270A,
- Qr0271W, Qy0134A, Qy0135W, Qy0214A, Qy0215W, Qy0274A,
- Qy0275W
Description
Dimensions:
- Weight: 0.15 lbs
- Length: 2.38 in
- Height: 3.13 in
- Width: 0.5 in
Product Overview:
Monitors ice formation during the production cycle. The Manitowoc 7601603 Ice Machine Thickness Probe Assembly 14" Lead is an OEM electronic sensing assembly that provides the control system with sensing information from the evaporator area. The assembly detects the developing ice condition and communicates the sensing input through its lead to the associated control circuitry. This information allows the equipment to recognize changes in ice formation and determine when the operating sequence should progress to the next stage.
Ice Thickness Monitoring:
Senses the changing condition of ice as it forms, the thickness probe provides an input that the control system can interpret during the production sequence. Its sensing function is associated with the evaporator area, where ice develops during normal operation. The resulting signal gives the control system information about the state of ice formation without performing any mechanical ice-forming function.
Harvest Cycle Control:
Supports the transition between ice production and harvest, the thickness probe supplies the control system with information associated with the monitored ice condition. The control system uses this input as part of its programmed operating sequence to recognize when the production stage should change. This sensing function provides the information required for the equipment to distinguish the ice-making stage from the subsequent harvest stage.
Replacement Guidelines:
The Manitowoc 7601603 Ice Machine Thickness Probe Assembly should be considered for replacement when the equipment does not respond to the expected ice-thickness sensing condition or when the production sequence becomes inconsistent. Damage to the sensing component or its lead can affect the signal provided to the control system. When selecting a replacement, verify manufacture, SKU, the complete equipment model, and applicable parts documentation to confirm the correct application.
Common Failure Symptoms:
- Ice production continues beyond the expected operating stage.
- Harvest begins at an inconsistent point in the ice-making cycle.
- Ice thickness varies noticeably between production cycles.
- The equipment does not transition from freeze to harvest as expected.
- The control system does not recognize the expected ice formation condition.
- Ice-making cycles become irregular or inconsistent.
Equipment Compatibility:
The Manitowoc 7601603 Ice Machine Thickness Probe Assembly 14" Lead is an OEM sensing component intended for applicable Manitowoc commercial ice machines. Verify the complete equipment model number, probe configuration, lead requirements, and part number against Manitowoc's parts documentation before purchasing.
Technical Specifications:
Brand: Manitowoc
Part Number: 7601603
Product Type: Ice Machine Thickness Probe Assembly
Lead Length: 14"
MANITOWOC:
76-0160-3 MAN7601603
Step1: Turn off ice machine power and water supply before starting installation.
Step2: Locate the existing thickness probe in the ice machine.
Step3: Disconnect wiring and remove the old probe carefully.
Step4: Inspect the mounting area and clean if needed.
Step5: Install the new probe assembly in the same position.
Step6: Reconnect wiring securely.
Step7: Restore power and water supply.
Step8: Test for accurate sensing and proper operation.
-
What maintenance is required for the Manitowoc 7601603 Thickness Probe Assembly?
Inspect the probe and lead for debris, mineral buildup, or damage. Ensure the probe tip is properly positioned and the lead connections are secure. Test readings periodically against a reliable thermometer to confirm accurate ice thickness measurements.
-
What are common issues with the Manitowoc 7601603 Ice Machine Thickness Probe Assembly?
- Incorrect ice thickness readings.
- Probe not detecting ice consistently.
- Loose or damaged lead wire.
- Delayed response in the ice cycle.
-
What maintenance is required for the Manitowoc 7601603 Ice Thickness Probe Assembly?
Regularly clean the probe to remove ice buildup and debris. Check electrical connections for corrosion or damage. Calibrate periodically to ensure accurate readings. Proper maintenance prevents measurement errors and ensures accurate ice machine thickness monitoring.
-
What are the common issues with the Manitowoc 7601603 Ice Thickness Probe Assembly?
- Inaccurate ice thickness readings.
- Corroded or loose electrical connections.
- Probe sensor damage from impact.
- Intermittent or failed signal transmission.
Customer Reviews
Write a Review
-
Precise Measurements
Easy setup, delivers accurate ice levels
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More