Description

The Adcraft LCCM200300000 Hi-Limit Thermostat is an essential part designed to protect the compatible commercial cooking equipment from overheating. Featuring a 1/4-inch by 4-1/2-inch sensing element, 3/8-inch MPT connection, and 30-inch capillary it monitors internal temperatures and interrupts operation when heat exceeds the 450°F limit. This component is commonly used in heated foodservice appliances installed in restaurants and kitchen operations. Within the system it operates as a safety control component that supports regulating temperature conditions and protects heating and electrical components during continuous operation.

Dimensions:

  • Weight: 0.45 lbs

This Part Fits the Following Models

155 models
Atosa ATFS-40 Atosa ATFS-50 Atosa ATFS-75 Vulcan Hart 1 Vulcan Hart 1G4BD Vulcan Hart 1G6BD Vulcan Hart 1G8BD Vulcan Hart 1GR35M Vulcan Hart 1GR45A Vulcan Hart 1GR45C Vulcan Hart 1GR45CF Vulcan Hart 1GR45D Vulcan Hart 1GR45DF Vulcan Hart 1GR45M Vulcan Hart 1GR65A Vulcan Hart 1GR65C Vulcan Hart 1GR65D Vulcan Hart 1GR65M Vulcan Hart 1GR85A Vulcan Hart 1GR85C Vulcan Hart 1GR85CF Vulcan Hart 1GR85D Vulcan Hart 1GR85DF Vulcan Hart 1GR85M Vulcan Hart 1GRC35 Vulcan Hart 1GRC45 Vulcan Hart 1GRC65 Vulcan Hart 1GRD45 Vulcan Hart 1GRD65 Vulcan Hart 1GRS35 Vulcan Hart 1GRS45 Vulcan Hart 1GRS65 Vulcan Hart 1HG35M Vulcan Hart 1HG45C Vulcan Hart 1HG45D Vulcan Hart 1HG45M Vulcan Hart 1HG65C Vulcan Hart 1HG65D Vulcan Hart 1HG65M Vulcan Hart 1HG85C Vulcan Hart 1HG85D Vulcan Hart 1HG85M Vulcan Hart 2G4BDF Vulcan Hart 2G6BDF Vulcan Hart 2G8BDF Vulcan Hart 2GR45AF Vulcan Hart 2GR45CF Vulcan Hart 2GR45DF Vulcan Hart 2GR45MF Vulcan Hart 2GR65AF Vulcan Hart 2GR65CF Vulcan Hart 2GR65DF Vulcan Hart 2GR65MF Vulcan Hart 2GR85AF Vulcan Hart 2GR85CF Vulcan Hart 2GR85DF Vulcan Hart 2GR85MF Vulcan Hart 2HG45CF Vulcan Hart 2HG45DF Vulcan Hart 2HG45MF Vulcan Hart 2HG65CF Vulcan Hart 2HG65DF Vulcan Hart 2HG65MF Vulcan Hart 2HG85CF Vulcan Hart 2HG85DF Vulcan Hart 2HG85MF Vulcan Hart 2XG45CF Vulcan Hart 2XG45DF Vulcan Hart 2XG4BDF Vulcan Hart 2XG65CF Vulcan Hart 2XG65DF Vulcan Hart 2XG6BDF Vulcan Hart 2XG85CF Vulcan Hart 2XG85DF Vulcan Hart 2XG8BDF Vulcan Hart 3G4BDF Vulcan Hart 3G6BDF Vulcan Hart 3G8BDF Vulcan Hart 3GR45AF Vulcan Hart 3GR45CF Vulcan Hart 3GR45DF Vulcan Hart 3GR45MF Vulcan Hart 3GR65AF Vulcan Hart 3GR65CF Vulcan Hart 3GR65DF Vulcan Hart 3GR65MF Vulcan Hart 3GR85AF Vulcan Hart 3GR85CF Vulcan Hart 3GR85DF Vulcan Hart 3GR85MF Vulcan Hart 4G4BDF Vulcan Hart 4G6BDF Vulcan Hart 4G8BDF Vulcan Hart 4GR45AF Vulcan Hart 4GR45CF Vulcan Hart 4GR45DF Vulcan Hart 4GR45MF Vulcan Hart 4GR65AF Vulcan Hart 4GR65CF Vulcan Hart 4GR65DF Vulcan Hart 4GR85AF Vulcan Hart 4GR85CF Vulcan Hart 4GR85DF Vulcan Hart 7494 Vulcan Hart 7495 Vulcan Hart 7594 Vulcan Hart 7595 Vulcan Hart EF3 Vulcan Hart EF4 Vulcan Hart EF5 Vulcan Hart GHF91E Vulcan Hart GHF91G Vulcan Hart GHF92E Vulcan Hart GHF92G Vulcan Hart GR25 Vulcan Hart GR35 Vulcan Hart GR35F Vulcan Hart GR45 Vulcan Hart GR45F Vulcan Hart GR65 Vulcan Hart GR65F Vulcan Hart GR85 Vulcan Hart GR85F Vulcan Hart GRC35F Vulcan Hart GRC45F Vulcan Hart GRC65F Vulcan Hart GRC85F Vulcan Hart GRD35F Vulcan Hart GRD45F Vulcan Hart GRD65F Vulcan Hart GRD85F Vulcan Hart GRS35F Vulcan Hart GRS45F Vulcan Hart GRS65F Vulcan Hart GRS85F Vulcan Hart HF91E Vulcan Hart HF91G Vulcan Hart HF92E Vulcan Hart HF92G Vulcan Hart LG300 Vulcan Hart LG400 Vulcan Hart LG500 Vulcan Hart TK35 Vulcan Hart TK45 Vulcan Hart TK65 Vulcan Hart VF1 Vulcan Hart VF1D Vulcan Hart VF2 Vulcan Hart VF2D Vulcan Hart VF90 Vulcan Hart VFD90 Vulcan Hart VMF1 Vulcan Hart VMF1D Vulcan Hart VMF2 Vulcan Hart VMF2D
Showing of 155.0
Provides high-temperature safety monitoring within compatible commercial kitchen equipment. The Adcraft LCCM200300000 Hi-Limit Thermostat 450°F 30" CAP detects excessive temperature through its sensing assembly and responds when the specified 450°F limit is reached. The 30-inch capillary connects the sensing element to the thermostat body, allowing temperature changes to be transmitted to the switching mechanism. When the safety threshold is reached, the thermostat interrupts the heating circuit to limit further heat input. It operates as an independent safety control alongside the equipment's primary temperature regulation system.

Overtemperature Protection:
Monitors temperature conditions and interrupts the heating circuit when the sensed temperature reaches the 450°F safety limit. The sensing assembly responds to temperature changes and transfers the thermal response through the capillary system to the thermostat mechanism. Once the specified limit is reached, the electrical contacts change state to stop power to the connected heating circuit. This independent cutoff function provides an additional layer of temperature control during abnormal or excessive heating conditions.

Safety Circuit Control:
Controls electrical continuity to the heating system when the detected temperature reaches the designated high-limit point. By interrupting the heating circuit during an overtemperature condition, the thermostat prevents continued heat input beyond its specified safety threshold.

Replacement Guidelines:
Replacement of the Hi-Limit Thermostat if it is damaged, unresponsive, worn, or no longer provides the intended high-temperature limit response. The part number LCCM200300000, 450°F temperature rating, and 30" capillary should be verified before replacement to ensure the correct hi-limit thermostat is selected. Replace the thermostat if deterioration affects temperature response, limit control, capillary integrity, electrical connection, or normal equipment operation.

Common Failure Symptoms:

  • Heating operation stops unexpectedly.
  • Heating components do not receive power.
  • Hi-limit protection does not respond correctly.
  • Incorrect high-temperature cutoff response.
  • Damaged or deteriorated capillary tube.
  • Visible damage to the thermostat assembly.

Equipment Compatibility:
The Adcraft LCCM200300000 Hi-Limit Thermostat is designed for compatible commercial kitchen equipment requiring a 450°F hi-limit thermostat with a 30-inch capillary. Verify the equipment model, part number, temperature rating, capillary length, and thermostat configuration before purchase.

Technical Specifications:
Brand: Adcraft
Part Number: LCCM200300000
Component Name: Hi-Limit Thermostat
Temperature Rating: 450°F
Capillary Length: 30" CAP

ADCRAFT:

LCCM2003000

ATOSA:

301030005 ATSA301030005

AVANTCO:

177400046 400046

ENTR?E:

400046

MAXX COLD:

16031A

U-LINE:

LCCM20030000

PATRIOT COOKING:

PT-20101F004

Step 1: Prior to starting the installation, ensure that the appliance is disconnected from the power source.

Step 2: Identify the current hi-limit thermostat located within the control or heater compartment of the equipment.

Step 3: Detach the old thermostat by disconnecting the wires and removing the fasteners used for mounting.

Step 4: Examine the replacement unit (LCCM200300000) alongside the original to confirm that it fits correctly and that the terminal arrangement matches.

Step 5: Install the new thermostat in the same location as the previous one, utilizing the appropriate screws or clips for secure mounting.

Step 6: Connect the wires to the designated terminals, making sure that the connections are tight and secure.

Step 7: Ensure that any sensing bulb or probe is positioned correctly in accordance with the specifications provided by the manufacturer.

Step 8: Reconnect the power supply and verify the functionality of the thermostat by heating the appliance to the required temperature and checking that it properly cuts off.
  • What signs indicate that the Hi-Limit Oven Thermostat might be malfunctioning?

    Signs of a malfunctioning thermostat can include inconsistent temperature readings, overheating, longer cooking times, or frequent triggering of the safety switch. If you notice any of these issues, consider inspecting or replacing the thermostat.

  • Can the Hi-Limit Oven Thermostat be repaired, or does it need replacement if faulty?

    In most cases, a faulty thermostat requires replacement rather than repair. Replacement ensures that the safety features and temperature control of the oven remain reliable.

  • Can I use a non-Adcraft thermostat as a replacement in my Adcraft oven?

    It's recommended to use genuine Adcraft replacement parts, including thermostats, to ensure proper fit and compatibility. Non-Adcraft thermostats may not provide the same level of performance or safety.

  • What maintenance is required for the Adcraft LCCM200300000 Hi-Limit Thermostat?

    Regularly inspect the thermostat capillary tube and sensing bulb for kinks, corrosion, or damage that could affect temperature sensing. Clean surrounding components to prevent grease buildup and overheating. Test the cut-off function periodically to ensure it trips near 450°F. Always disconnect power before servicing to prevent electrical shock or burns.

  • What are common issues with the Adcraft LCCM200300000 Hi-Limit Thermostat?

    • Failure to shut off at the set temperature.
    • Erratic temperature readings.
    • Loose or corroded electrical connections.
    • Sensor or cap damage affecting performance.

  • When should the Imperial 20160 Convection Oven Door Closing Mechanism be replaced?

    The door closing mechanism should be replaced when it is worn, damaged, loose, or no longer allows the oven door to close and remain securely positioned.

  • What does the Adcraft LCCM200300000 hi-limit thermostat do?

    It monitors equipment temperature and interrupts the heating circuit when the sensed temperature reaches its specified 450°F safety limit.

  • What are common signs of a faulty hi-limit thermostat?

    Unexpected heating interruptions, incorrect temperature cutoff, failure to interrupt heating, inconsistent safety response, or visible component damage may indicate a problem.

  • Can a damaged capillary affect temperature detection?

    Yes. Kinks, bends, physical damage, or deterioration can interfere with the sensing response and affect high-temperature protection.

  • Why is a hi-limit thermostat used with a primary temperature control?

    The hi-limit thermostat provides a separate safety control point, allowing the heating circuit to be interrupted if temperature rises beyond the normal operating range.

Customer Reviews

5 Based on 13 reviews
5 ★
13
4 ★
0
3 ★
0
2 ★
0
1 ★
0
13 reviews
  • Accurate Response
    Ava —

    It responds correctly under high heat conditions, preventing overheating.

  • Quick Fix
    James —

    Shuts down heat instantly at set temperature.

  • Quiet Operation
    Wade Bergman —

    Effortlessly handles overheating, very satisfied

  • Stable Temperature
    Douglas —

    Simple fix, oven working like new

  • Efficient Control
    Freodhoric —

    Efficient and easy temperature control

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More