Vulcan Hart 00-498025 Gas Range Pilot Safety Valve Baso
Dimensions
- Weight: 0.644 lbs
Pilot Gas Flow Control:
Regulates gas supplied to the pilot assembly based on the operating condition of the pilot flame. The valve helps maintain controlled gas delivery during the pilot stage and limits continued gas flow when the required flame condition is absent.
Replacement Guidelines:
Replace the Gas Griddle Pilot Safety Valve if it is damaged, corroded, leaking, or no longer provides proper pilot gas control. The part number 00-498025 and Baso valve configuration should be verified before replacement to ensure the correct pilot safety valve is selected. Replace the valve if deterioration affects gas flow control, connection integrity, pilot operation, or normal range operation. Gas-system service should be performed by a qualified technician.
Common Failure Symptoms:
Equipment Compatibility:
The Vulcan Hart 00-498025 Gas Griddle Pilot Safety Valve is an OEM component designed for Vulcan Hart commercial gas griddles using the corresponding pilot safety valve arrangement. Verify the equipment model and gas-control configuration before selecting the component.
Technical Specifications:
Part Number: 00-498025
Brand: Vulcan Hart
Component Name: Pilot Safety Valve
Equipment Type: Commercial Gas Cooking Equipment
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Step1: Turn off the gas supply and disconnect power to the appliance.
Step2: Allow the unit to cool completely before servicing.
Step3: Access the safety valve and label, then disconnect the gas lines and thermocouple.
Step4: Remove mounting screws and carefully take out the old valve.
Step5: Install the new valve, secure it, and reconnect the gas lines and thermocouple.
Step6: Restore gas supply, check for leaks, and test secure operation.