Cleveland 22122 Steamer Pressure Relief Valve 5-15 lbs 3/4" FPT

SKU: 22122 1-22122 Brand: Availability:
Out of Stock
(0)

$881.39 Price reduced from $1,085.46
Save $204.07


Have a Question? +1 (866) 863-0907

Specifications:

  • Steam Pressure Relief Valve
  • Watts 3/4" Fpt
  • Max. Inlet Pres. 60 Lbs., Max Temp 300 F,
  • Painted Iron Body~
  • 4-5/8" Across From Inlet To Outlet,
  • Adjustable Range: 5 To 15 Lbs.
  • Watts "0830915 3/4" 152Az1"
  • For Repair Kit Use # 51-1469
  • Cleveland
  • Market Forge
  • Steamer A, A-1, Jet(A,B), Mark-Fore, St-As(D,E,F,G,H),
  • Modular Gas Steam Generators, M24E(18,24,32,36,42,48),
  • M36E(18,24,32,36,42,48).

Description

Cleveland 22122 Pressure Relief Valve with 3/4” FPT and is used to prevent dangerous pressure build-up in Steamer systems. It works under a pressure range of 5 to 15 lbs and self-relieves pressure to avoid damaging the equipment. This valve keeps pressure levels constant, facilitating better steam production without the potential danger of increased pressure affecting the system. Designed for use in steamers and other steam applications, it increases safety, prolongs equipment’s life, and improves performance by eliminating pressure that could cause equipment failure.

Dimensions:

  • Weight: 12.1 lbs
  • Length: 9 in
  • Height: 6 in
  • Width: 6.5 in

This Part Fits the Following Models

98 models
Cleveland 24CDM Cleveland 24CDP10 Cleveland 2DE Cleveland 2DE24 Cleveland 2DG Cleveland 2DG24 Cleveland 2DLE Cleveland 2DLG Cleveland 2DLLE Cleveland 2DLLG Cleveland 2DQTE Cleveland 2DQTG Cleveland 2DQTLE Cleveland 2DQTLG Cleveland 2DQTLLE Cleveland 2DQTLLG Cleveland 2DQTS Cleveland 2DQTSC Cleveland 2DS Cleveland 2DS24 Cleveland 2DSC Cleveland 2DSC24 Cleveland 36CDM Cleveland PDL-2J Cleveland PDL-2K Cleveland PDL-3J Cleveland PDL-3K Cleveland PDM-2J Cleveland PDM-2K Cleveland PDM-3J Cleveland PDM-3K Cleveland PDP-2J Cleveland PDP-2K Cleveland PDP-3J Cleveland PDP-3K Cleveland PEM160-2J Cleveland PEM160-3J Cleveland PEM200-2J Cleveland PEM200-3J Cleveland PEM24-2J Cleveland PEM24-2K Cleveland PEM24-3J Cleveland PEM24-3K Cleveland PEM250-2J Cleveland PEM250-3J Cleveland PEM300-2J Cleveland PEM300-3J Cleveland PEM36-2J Cleveland PEM36-2K Cleveland PEM36-3J Cleveland PEM36-3K Cleveland PEM48-2J Cleveland PEM48-2K Cleveland PEM48-3J Cleveland PEM48-3K Cleveland PGM160-2K Cleveland PGM160-3K Cleveland PGM200-2K Cleveland PGM200-3K Cleveland PGM250-2K Cleveland PGM250-3K Cleveland PGM300-2K Cleveland PGM300-3K Cleveland PSM-2J Cleveland PSM-2K Cleveland PSM-3J Cleveland PSM-3K Vulcan Hart C24DA10 Vulcan Hart C24DA6 Vulcan Hart C24GA10 Vulcan Hart C24GA6 Vulcan Hart MHB24E Vulcan Hart MHB24G Vulcan Hart VHL2D Vulcan Hart VHL2E Vulcan Hart VHL2G Vulcan Hart VHL3D Vulcan Hart VHL3E Vulcan Hart VHL3G Vulcan Hart VHX24D Vulcan Hart VHX24D5 Vulcan Hart VHX24E Vulcan Hart VHX24E5 Vulcan Hart VHX24G Vulcan Hart VHX24G5 Vulcan Hart VSCDA2 Vulcan Hart VSCDA3 Vulcan Hart VSX24D Vulcan Hart VSX24E Vulcan Hart VSX24G Vulcan Hart VSX36D Vulcan Hart VSX36E Vulcan Hart VSX36G Vulcan Hart VSX36R Vulcan Hart VSX42DT Vulcan Hart VSX42ET Vulcan Hart VSX42GT Vulcan Hart VSX42RT
Showing of 98.0

HOBART:

00-880028 880028

VULCAN HART:

00-880028 880028

Step1: Turn off power, shut off water supply, and release all pressure from the unit before servicing.

Step2: Remove the old pressure relief valve using the proper wrench while supporting connected piping.

Step3: Apply approved thread sealant to the new valve threads without blocking the opening.

Step4: Install and tighten the new valve securely in the correct orientation.

Step5: Restore utilities and test for leaks, proper pressure release, and safe operation.

  • What maintenance is required for the Cleveland 22122 Pressure Relief Valve?

    Regularly inspect the steamer valve for scale buildup, corrosion, or debris that may affect pressure release. Test the valve periodically to ensure proper operation. Clean internal components as needed and verify pressure settings. Always follow safety procedures when handling pressurized steam equipment.

  • What are common issues with the Cleveland 22122 Pressure Relief Valve?

    • Steamer valve failing to open at designated pressure levels.
    • Steam leakage from the valve seat or connections.
    • Blockage due to mineral or scale buildup.
    • Inconsistent pressure release or delayed activation.
    • Wear or damage to internal spring mechanism.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More