Rankin Delux RDLR-10 Charbroiler Top Burner Valve In-1/8" Out-3/8" NPT

SKU: RDLR-10 1-RDLR-10 Brand: Availability:
Out of Stock
(0)

$23.62 Price reduced from $36.20
Save $12.58


Have a Question? +1 (866) 863-0907

Specifications:

  • ***For Vulcan Hart Use Ap# 8012180***
  • Gas In: 1/8" Npt~
  • Gas Out: 3/8-27. Off/On, #46 Hood Orifice
  • & Point, Adjustable, Brass
  • Not Push To Turn Stem: 1-3/16" Long~
  • D Stem 1/4". Knob
  • #22-1464 Or #22-1164 Depending On Model. Use #26-2937 To
  • Convert Valve To 3/8" Cct On Some Models.
  • Nat Orifice # 26-1117 Is #57, Nat Orifice # 26-1780 Is #56,
  • Lp Orifice # 26-1080 Is #72.
  • Anets Broiler Br34-3
  • Imperial Broiler Series: Eba, Gd, Icb, Icma, Irb, Isb, Msq,
  • Iab(E)(R)(S). Grill Series: Ihr, Imga.
  • Range Series: Icra, Ihpa, Ihr, Ir, Ispa.
  • Roaster Series: Ipr, Ipra.

Description

The Rankin Delux RDLR-10 Charbroiler Top Burner Valve NPT In-1/8" Out-3/8" is intended to control flow with a top-mounted burner connection with an inlet of 1/8" NPT and an outlet of 3/8". It is fitted in parallel with the existing piping to offer a regulated control on the supplied medium. The valve is included in the flow control network of the system, and it can be adjusted manually with the alignment of the fittings. It has the purpose of maintaining a steady and regulated supply via the burner supply path.

Dimensions:

  • Weight: 0.2 lbs
  • Length: 0.88 in
  • Height: 3.5 in
  • Width: 1.88 in

This Part Fits the Following Models

100 models
Rankin Delux 2300 Rankin Delux RB8 Rankin Delux RD90-72-C Rankin Delux RDGM Rankin Delux RDGM-12-1-C Rankin Delux RDGM-12-A-C Rankin Delux RDGM-12-B-C Rankin Delux RDGM-24-1-C Rankin Delux RDGM-24-A-C Rankin Delux RDGM-24-B-C Rankin Delux RDGM-36-1-C Rankin Delux RDGM-36-A-C Rankin Delux RDGM-36-B-C Rankin Delux RDGM-48-A-C Rankin Delux RDGM-48-B-C Rankin Delux RDGM-60-B-C Rankin Delux TB-8 Rankin Delux TB-815-C Rankin Delux TB-821-C Rankin Delux TB-825-C Rankin Delux TB-830-C Rankin Delux TB-836-C Rankin Delux TB-841-C Rankin Delux TB-846-C Rankin Delux TB-860-C Rankin Delux TB-872-C Rankin Delux TB-884-C Bakers Pride 99-5702 Bakers Pride 99-5704 Bakers Pride C-24GS Bakers Pride C-24R Bakers Pride C-30GS Bakers Pride C-30R Bakers Pride C-36GS Bakers Pride C-36R Bakers Pride C-48GS Bakers Pride C-48R Bakers Pride C-60GS Bakers Pride C-60R Bakers Pride C-72GS Bakers Pride C-72R Bakers Pride C-84GS Bakers Pride C-84R Bakers Pride CBBQ-30S Bakers Pride CBBQ-60S Bakers Pride CH-10 Bakers Pride CH-12 Bakers Pride CH-14 Bakers Pride CH-16 Bakers Pride CH-18 Bakers Pride CH-20 Bakers Pride CH-22 Bakers Pride CH-4 Bakers Pride CH-6 Bakers Pride CH-8 Bakers Pride CTB-24 Bakers Pride CTB-24GS Bakers Pride CTB-24R Bakers Pride CTB-36 Bakers Pride CTB-36GS Bakers Pride CTB-36R Bakers Pride CTB-48 Bakers Pride CTB-48GS Bakers Pride CTB-48R Bakers Pride CTB-60 Bakers Pride CTB-60GS Bakers Pride CTB-60R Bakers Pride CTB-72 Bakers Pride CTB-72GS Bakers Pride CTB-72R Bakers Pride F-24GS Bakers Pride F-24R Bakers Pride F-30GS Bakers Pride F-30R Bakers Pride F-36GS Bakers Pride F-36R Bakers Pride F-48GS Bakers Pride F-48R Bakers Pride F-60GS Bakers Pride F-60R Bakers Pride F-72GS Bakers Pride F-72R Bakers Pride F-84GS Bakers Pride F-84R Bakers Pride FLB-24 Bakers Pride FLB-24GS Bakers Pride FLB-24R Bakers Pride FLB-36 Bakers Pride FLB-36GS Bakers Pride FLB-36R Bakers Pride FLB-48 Bakers Pride FLB-48GS Bakers Pride FLB-48R Bakers Pride FLB-60 Bakers Pride FLB-60GS Bakers Pride FLB-60R Bakers Pride FLB-72 Bakers Pride FLB-72GS Bakers Pride FLB-72R Bakers Pride L-24GS
Showing of 100.0

Step1: Turn off the gas supply and ensure the burner is cool.

Step2: Remove the existing burner valve by loosening the mounting screws and disconnecting the gas line.

Step3: Position the new valve in place and secure it with screws.

Step4: Reconnect the gas line, ensuring a tight, leak-free connection.

Step5: Test for leaks with a soapy water solution before lighting the burner.

Step6: Turn on the gas and verify proper flame operation.

  • What maintenance is required for the Rankin Delux RDLR-10 Top Burner Valve?

    Regularly inspect the valve for leaks and corrosion. Clean any debris or grease from the valve body. Operate the valve occasionally to ensure smooth movement. Always shut off the gas supply before performing any maintenance for safety.

  • What are common issues with the Rankin Delux RDLR-10 Top Burner Valve?

    • Difficulty turning the valve handle.
    • Gas leaks at the connection points.
    • Inconsistent flame or flow.
    • Worn or damaged internal seals.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More