Manitowoc 000002106 Ice Machine Water Trough

SKU: 000002106 1-000002106 Brand: Availability:
In Stock
(0)

$100.67 Price reduced from $145.95
Save $45.28


Have a Question? +1 (866) 863-0907

Description

Manitowoc 000002106 Ice Machine Water Trough is an essential part intended to provide water for the production of ice in Manitowoc ice machines. This means there is constant water supply in this trough which enable fast consistent ice making processes. The two-chamber construction provides for the proper water supply and, therefore, the improved work of the machine. Advantages include better quality of ice, less time is taken in maintenance and the ice machine will last longer. This product is necessary where there is need to ensure constant supply of ice for use in foods and drinks.

Dimensions:

  • Weight: 1.7 lbs
  • Length: 21 in
  • Height: 3 in
  • Width: 13 in

Product Overview:
Holds water within the ice-making section. The Manitowoc 000002106 Ice Machine Water Trough is an OEM water-management component that provides a designated water-retention area for compatible commercial ice machines. The trough forms part of the equipment's water-management arrangement and maintains water availability within the ice-making compartment during the production cycle. Its passive structure supports the intended location of water within the system without actively pumping or electrically controlling water.

Water Distribution:
Retains water in the designated ice-making area, the water trough maintains a defined location for water supplied to the ice-making system during operation. Its position supports the intended relationship between the water-retention area and associated water-distribution components as the production cycle progresses. The trough provides physical water containment rather than performing an active circulation or control function.

Ice Making Water Management:
Maintains water availability within the ice-making compartment, the trough contributes to the water-management arrangement required during ice production. Its passive function provides a contained area where water can remain available to the ice-making system. Proper condition of the trough preserves the intended water-holding arrangement and supports the physical water-management requirements of the equipment.

Replacement Guidelines:
Replacement may be necessary when the water trough develops cracks, warping, or other damage that compromises its ability to hold water. Leakage or deterioration can disturb the intended water arrangement around the evaporator and affect the production cycle. For the Manitowoc 000002106 Ice Machine Water Trough, confirm the complete equipment model and applicable parts documentation before purchasing to ensure the replacement matches the required application.

Common Failure Symptoms:

  • Water leaking from the trough area.
  • Water failing to remain within the designated trough.
  • Irregular water availability during the ice-making cycle.
  • Visible cracking or deformation.
  • Water appearing outside the intended water-holding area.
  • Ice production affected by abnormal water management.

Equipment Compatibility:
The Manitowoc 000002106 Ice Machine Water Trough is an OEM water-management component intended for applicable Manitowoc commercial ice machines. Verify the complete equipment model number, water trough configuration, and part number against Manitowoc's parts documentation before purchasing.

Technical Specifications:
Brand: Manitowoc
Part Number: 000002106
Product Type: Water Trough
Application: Commercial Ice Machine

MANITOWOC:

2106 MAN000002106 MAN2106

Step1: Turn off the ice machine and unplug it.

Step2: Remove the old trough carefully.

Step3: Clean the area thoroughly to remove debris.

Step4: Position the new water trough in the correct orientation.

Step5: Align it with the water inlet and ice chute.

Step6: Secure the trough using mounting brackets or clips provided.

Step7: Reconnect the water line and check for leaks.

Step8: Power on the machine and observe proper ice production.

  • What maintenance is required for the Manitowoc 000002106 Water Trough?

    Regularly inspect the ice machine water trough for cracks, leaks, or mineral buildup. Clean with mild detergent to prevent contamination and ensure proper water flow. Check seals and connections to avoid leaks, and always follow safety guidelines when handling cleaning solutions.

  • What are common issues with the Manitowoc 000002106 Water Trough?

    • Mineral or lime scale buildup affecting water flow.
    • Cracks or leaks causing water loss.
    • Clogged or blocked drainage.
    • Loose or worn seals reduce efficiency.