Montague 2038-9 Air Shutter

SKU: 2038-9 1-2038-9 Brand: Availability:
In Stock
(0)

$8.74 Price reduced from $9.33
Save $0.59


Have a Question? +1 (866) 863-0907

Specifications:

  • Air Shutter, Twin Plate, 2 Slots, .463" Orifice Hole, Fits
  • 2.092" Dia Burner, W/ Locking Ears, 2-1/4"Od Air Shutter
  • For Cast Iron Burner.
  • Magikitch'N Charbroiler Series Dmc, Fm-Smb, Smb, Smb-Apm
  • Montague Broiler Ufc, Ufsc, Ufscc, Ufsmc (24 To 72, >10/91
  • Grill 2436, 2436T, 2472, 2472T, Grizzly G.
  • Range 136-5, 136-559~
  • Series:
  • Vulcan
  • Broiler Hcb1 (Old Cb-1L), Hcb2 (Old Cb-2L), Hcb44
  • (Old7844L), Hcbo40 (Old 7840Al), M7806, M7809, Series: Hgb.
  • Range 7830.
  • Wolf Oven

Description

The Montague 2038-9 Air Shutter is used to control combustion by changing the air opening that combines with gas before ignition to allow the flame to be established with a regulated proportion of air to fuel. The size of the intake is adjusted by rotation or positioning of the shutter, which varies the amount of primary air that reaches the burner. The element is fitted on the venturi of the burner of compatible gas cooking equipment, which connects to standard burner fittings and is clamped down when installed.

Dimensions:

  • Weight: 0.15 lbs
  • Length: 0.81 in
  • Height: 0.12 in
  • Width: 0.81 in

ANETS:

-P9300-10 P9300-10

COMSTOCK CASTLE:

-16000 -25 16000 25

MAGIKITCH'N:

-30-05-00395 -30-05-00395-A -3005-0039500 -300500395 -300500395A

MONTAGUE:

-02038-9 -2038-9 -B-26 -B26 -G-11 -G11 -R-26 -R26 02038-9 B-26 B26 G-11 G11 MON2038-9 MONB26 MONG11 MONR26 R-26 R26

PITCO:

-P9300-10 P9300-10

SOUTHBEND:

-1127299 1127299

VULCAN HART:

-00-404060-00001 -00-719241 -104060-1 -19241 -404060-00001 -404060-1 -719241 00-404060-00001 00-719241 104060-1 19241 404060-00001 404060-1 6470 719241 806470 VH104060-1 VH404060-1 VH6470 VH806470

Step1: Turn off gas supply and allow burner assembly to cool completely before starting.

Step2: Remove existing twin plate air shutter and inspect burner orifice for debris or damage.

Step3: Align the new twin plate air shutter with mounting slots and secure using original fasteners.

Step4: Adjust air opening to match orifice alignment for proper flame.

Step5: Restore gas supply and test ignition, checking flame stability and color.

  • What maintenance is required for the Montague 2038-9 Burner Twin Plate Air Shutter?

    Regularly inspect the air shutter for grease buildup, debris, or corrosion and clean it using a non-abrasive brush. Ensure the slots and orifice remain unobstructed for proper airflow. Tighten fittings and check alignment periodically. Always turn off gas supply before servicing.

  • What are common issues with the Montague 2038-9 Burner Twin Plate Air Shutter?

    • Improper air-to-gas mixture causing yellow or uneven flames.
    • Blocked orifice hole restricting gas flow.
    • Misaligned shutter plates affecting combustion efficiency.
    • Corrosion or wear leading to inconsistent burner performance.

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More