Vulcan Hart 00-412788-00060 Range Thermocouple

SKU: 00-412788-00060 1-00-412788-00060 Brand: Availability:
In Stock
(13)

$41.38 Price reduced from $53.75
Save $12.37


Have a Question? +1 (866) 863-0907

Description

The Vulcan Hart 00-412788-00060 Thermocouple is a safety part that is essential in controlling the gas flow in commercial ranges. It operates by detecting the heat of the pilot flame and producing a low level electricity current that maintains the gas valve open. In case of flame extinction, the thermocouple immediately closes the gas supply to avoid gas leakage. It resists the high heat conditions of a kitchen, this component provides safe ignition and effective functionality, which makes it a necessity in ensuring performance and compliance in Vulcan Hart gas range units.

Dimensions:

  • Weight: 0.5 lbs
Manufacturer Name: Vulcan Hart
Product Number: 00-412788-00060
OEM Part Number: 00-412788-00060
Product Description: Vulcan Hart 00-412788-00060 Thermocouple – your dependable companion for precise temperature control in heavy-duty cooking environments. Designed for professional kitchens and industrial settings, this 72-inch thermocouple boasts exceptional reliability and accuracy. With a voltage range of 20-30 Millivolts, it ensures consistent and safe temperature monitoring, making it an essential tool for any commercial kitchen. Crafted with precision, the Vulcan Hart thermocouple features coaxial thermocouple threads measuring 11/32"-32, ensuring a secure fit and easy installation. Its rugged construction can withstand the demands of a busy kitchen, making it a long-lasting investment for your business. Measuring a compact 3 inches in length, 2.5 inches in width, and 1 inch in height, this thermocouple is designed to fit seamlessly into your cooking equipment. Weighing just 0.4 pounds, it won't add unnecessary bulk while providing the accurate temperature readings you need. 

Key Features:

  • Heavy-duty 72-inch thermocouple for precise temperature control.
  • Wide voltage range of 20-30 Millivolts for reliable performance.
  • Coaxial thermocouple threads (11/32"-32) for secure installation.
  • Rugged construction designed to withstand commercial kitchen demands.
  • Compact dimensions (3"x2.5"x1") and lightweight (0.4 lbs) for easy integration.
  • Suitable for various commercial restaurant equipment.
Similar Models:M1296A - Bakers-Pride, M1296X - Bakers-Pride, 00-428305-00001 - Hobart, 428305-00001 - Hobart, 428305-1 - Hobart, 00-428305-00001 - Vulcan-Hart, 412788-60 - Vulcan-Hart, 428305-00001 - Vulcan-Hart, 428305-1 - Vulcan-Hart, VH00-428305-00001 - Vulcan-Hart
Dimensions:
Length:3in/7.62cm
Width:2.5in/6.35cm
Height:1in/2.54cm
Weight:0.4lbs/181.44g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from PartsFe!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at 866-863-0907 or contact@partsfe.com

 

BAKERS PRIDE:

AS-M1296A BKPM1296A BKPM1296X M1296A M1296X

COOKING PERFROMANCE GROUP:

351302170058

HOBART:

00-428305-00001 428305-00001 428305-1 HOB00-428305-00001 HOB428305-00001 HOB428305-1

Step1: Turn off the gas and allow the range to cool.

Step2: Locate the thermocouple near the burner pilot assembly.

Step3: Disconnect the thermocouple from the gas valve.

Step4: Remove the mounting bracket or screw holding the old thermocouple.

Step5: Install the new thermocouple in the same position and reconnect.

Step6: Restore gas supply and test pilot operation and safety perform.

  • What is a thermocouple, and how does it work?

    A thermocouple is a temperature sensor that produces a voltage proportional to the temperature difference between its two junctions. It relies on the Seebeck effect to generate a voltage when exposed to varying temperatures.

  • Where are thermocouples commonly used in commercial restaurant equipment?

    Thermocouples are frequently found in commercial ovens, grills, fryers, and refrigeration systems to monitor and control cooking and storage temperatures.

  • What maintenance is required for the Vulcan Hart 00-412788-00060 Thermocouple?

    Regularly inspect the thermocouple tip for carbon buildup, grease, or corrosion, and clean gently with fine sandpaper or cloth. Ensure it is properly positioned in the pilot flame. Turn off gas and power before servicing to prevent burns or leaks.

  • What are the common issues with the Vulcan Hart 00-412788-00060 Thermocouple?

    • Inaccurate temperature readings
    • Burner failing to stay lit
    • Loose or corroded connections
    • Intermittent operation is causing pilot light issues.

Customer Reviews

5 Based on 13 reviews
5 ★
13
4 ★
0
3 ★
0
2 ★
0
1 ★
0
13 reviews
  • Heating Normal
    Garrett —

    New thermocouple properly senses heat and keeps gas flowing.

  • Temperature Control
    Deborah —

    Replaced the old sensor and ignition works reliably now.

  • Simple Installation
    Ollaneg —

    Perfect replacement, highly recommend

  • Reliable Performance
    Bartholomeo —

    Perfect for precise thermal measurements

  • Durable
    Louis-Émery Beaulieu —

    Easy to install, Excellent for high-temperature applications

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More