Hobart 412212-00002 3-Way Pilot Tube 1/4" Flame NAT/LP

SKU: 412212-00002 1-412212-00002 Brand: Availability:
In Stock
(0)

$54.39 Price reduced from $70.64
Save $16.25


Have a Question? +1 (866) 863-0907

Specifications:

  • Nat/Lp Pilot, Factory # 6Ch14-10, 1830-491
  • Tube Size 1/4", Flame Pattern 3 Way, Hood Width 1-1/2"
  • Nat Orifice Pre-Installed # 26-1555, .018
  • Lp Orifice Included # 26-1554, .010
  • Cecilware Fryer Fmp 30, 40B, 403, 65, Fms 30, 54
  • Imperial Fryer Series: If, Ihr, Ir.
  • Vulcan Hart
  • Fryer Gf(91G,92G), Hf91G, Hf92G (Old 7891G & 7892G),Tk-35,
  • Series: 7400, 7500, 7800 (Depending On Date Of
  • Model). Series: Ef
  • 1Gr45M, 1Gr65M, 1Gr85M, 1Grc35, 1Grc45, 1Grc65, 1Grd45,
  • 1Grd65, 1Grs35, 1Grs45, 1Grs65, Ef3, Ef4, Ef5, Gr35, Gr35F,
  • Gr45, Gr45F, Gr65, Gr65F, Gr85, Gr85F, Grc35F, Grc45F,
  • Grc65F, Grc85F, Grd35F, Grd45F, Grd65F, Grd85F, Grs35F,
  • Grs45F, Grs65F, Grs85F

Description

The Hobart 412212-00002 3-Way Pilot Tube 1/4" Flame NAT/LP is a gas distribution component used in commercial cooking equipment ignition systems. It channels pilot gas to multiple points within the burner assembly to maintain a consistent flame for ignition and flame sensing. The tube is applied in appliances that operate on natural gas or liquid propane, where it supports accurate startups and steady pilot operation. Within the system, it connects to the pilot burner and safety controls, supporting ensuring proper ignition sequencing and stable flame performance during cooking equipment operation and routine maintenance process operations.

Dimensions:

  • Weight: 0.2 lbs
  • Length: 1.75 in
  • Height: 2.5 in
  • Width: 2 in

A pilot burner assembly designed for commercial gas fryers delivers a controlled ignition flame to light the main burner during cooking operations. This unit features a 1/4-inch tube connection with a 3-way flame pattern that spreads flame evenly across multiple ignition points. It comes with a pre-installed natural gas orifice sized at .018 and includes an LP orifice with a .010 opening for compatible LP gas setups. The 1-1/2-inch hood width allows proper flame direction inside pilot burner assemblies. Used in commercial fryers and gas cooking equipment, this pilot assembly is installed in restaurant kitchens, cafeterias, and foodservice cooking stations where steady burner ignition is required. A clogged or worn pilot assembly may lead to weak flame output, slow ignition, or burner startup issues. Replacing the pilot assembly can improve flame delivery and restore normal ignition operation in compatible equipment.

Equipment Compatibility:
Primary uses for Hobart NAT/LP Pilot assemblies include commercial fryers, gas-heated cooking equipment, and foodservice burner systems used in busy kitchen environments. This NAT/LP Pilot 412212-00002 is compatible with commercial equipment from leading brands such as Vulcan Hart, Imperial, Cecilware, Royal Range, Tri-Star, and Hobart, and more, where pilot flame ignition and burner startup control are required during operation. Brand Compatibility Replaces multiple part numbers used across commercial foodservice equipment brands including Cecilware, Grindmaster, Hobart, Imperial, Royal Range, Tri-Star, U-Line, Vulcan Hart, and other compatible commercial fryer and gas cooking equipment manufacturers. Complete cross-reference details are provided separately.

Brand Compatibility:

Product Specifications:
Manufacturer: Hobart
SKU: 412212-00002
Product Type: NAT/LP Pilot Assembly
Tube Size: 1/4"
Flame Pattern: 3 Way
Hood Width: 1-1/2"
Natural Gas Orifice: #26-1555 (.018) Pre-Installed
LP Orifice Included: #26-1554 (.010)
Application: Commercial Gas Fryers and Cooking Equipment

Key Features:

  • 3-way flame pattern spreads ignition flame across compatible burner sections.
  • 1/4-inch tube connection fits selected commercial fryer pilot systems.
  • Includes both natural gas and LP orifice options for compatible gas applications.
  • Pre-installed NAT orifice allows installation in natural gas configurations.
  • Pilot hood directs flame toward burner ignition areas during startup cycles.
  • Designed for commercial fryers and gas cooking systems exposed to repeated heating operations.

Technician Feedback:

“The pilot flame became more stable and the fryer started lighting faster after installation.”

Customer Reviews

No reviews yet. Be the first to write one!

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More