Hobart 721027-1 Thermopile 36" 2 Lead 250-750 MV
Specifications:
- 36" 2 Lead, Thermopile, 250-750 Mv, Robertshaw 1950-53B
- Cecilware Fryer Fmp 30, 40B, 403, 65, Fms 30, 54
- Cleveland Boiler Gas Steam Generators: W/O Probes (100,000
- Btu - 2 Burners~
- 150,000 - 3 Burners)~
- W/3 Probes (160,000
- Btu - 3 Burners~
- 200,000 - 4 Burners
- Groen Braising Pan Hfp/2. Series: Chfp, Nhfp.
- Imperial Fryer Series: If, Ihr, Ir.
- Keating Griddle Model 48Bfld
- Southbend Fryer Gfs, 4Fr-45
- Star Fryer 404A, 615Fa, 630Fa
- Tri-Star Fryer Tsf-3540, Tsf-4050, Tsf-6575
- Vulcan Fryer: Tk, Rs, Ghf (Old Hf) Gr, Grd, Grc,Grs,
- Wells Grill, Gas
- Wolf Fryer Wtf-35,
Description
Dimensions:
- Weight: 0.2 lbs
- Length: 3.5 in
- Height: 1 in
- Width: 2.5 in
ADCRAFT:
AMERICAN RANGE:
A11102 AMRA11102
ATOSA:
BLOOMFIELD:
CLEVELAND:
20410 CLE20410
ENTR?E:
400043-1
FRYMASTER:
810-0159 810-0617-1 810-06171 8100159 8100617-1 81006171 FM810-0159 FM810-0617-1 FM810-06171 FM8100159 FM8100617-1 FM81006171
GARLAND:
HOBART:
00-410839-00004 00-497301-00001 00-721027-00001 00-722158 21027-1 410839-00004 410839-4 497301-00001 497301-1 721027-00001 722158
IMPERIAL:
1096 IMP1096
JADE RANGE:
LANG:
MARKET FORGE:
SOUTHBEND:
STAR MFG:
2J-1182154 2J-80504-04 2J-Y9270 2T-42195 2T42195 42195 4T42195 62195 WS-62195 Y9270
STERO:
STA2T-42195 STA2T42195 STA42195
U-LINE:
1950-532 1950-53B
Step1: Shut off gas and electrical supply, then let burner assembly cool fully before handling.
Step2: Remove access cover and disconnect existing thermopile from pilot bracket and control valve terminals.
Step3: Install new thermopile, positioning tip directly in steady pilot flame for accurate millivolt generation.
Step4: Reconnect the leads securely to the gas valve.
Step5: Restore gas, light pilot, and confirm stable flame and ignition response.
Step6: Check all connections for leaks and secure panels before operation.
-
What maintenance is required for the Hobart 721027-1 Thermopile?
Inspect the thermopile tip regularly for carbon buildup or soot and clean it gently to ensure proper flame contact and stable millivolt output. Check all electrical connections for tightness, corrosion, or heat damage. Verify correct pilot flame engulfment for accurate energy conversion. Replace if output becomes inconsistent or falls below operating range.
-
What are common issues with the Hobart 721027-1 Thermopile?
- Weak or no millivolt output due to worn thermopile.
- Pilot flame not properly heating sensor tip.
- Carbon buildup reducing electrical generation efficiency.
- Loose or corroded wire connections causing signal loss.
- Intermittent burner operation from insufficient voltage output.
Customer Reviews
No reviews yet. Be the first to write one!
Write a Review
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More