Pitco P5045651 Fryer Natural Gas Safety Control Valve W/ 120 VAC Actuator, 3/4" FPT IN/OUT

SKU: P5045651 1-P5045651 Brand: Availability:
In Stock
(0)

$276.13 Price reduced from $541.00
Save $264.87


Have a Question? +1 (866) 863-0907

Specifications:

  • Nat Gas Safety, 3/4" Fpt In/Out, 300.000 Btu, (2) 3/4" X
  • 1/2" Reducer Bushings, 120 Vac Actuator, Blk & Wht Wires,
  • W/Eco Slotted Thermopile Magnet, Model 7000 Bmser-120
  • Thermopile, H231, T-103, # 51-1122, Screw In Type, 7/16-27
  • Brass Pile Holding Nut, 3/8-32 Thread, For Magnet, 750Mv,
  • 500Mv Under Load ,
  • Thermopile, Push On, For Frymaster, # 51-1348.
  • Frymaster Fryer Mac(50,150,250,350), Mj(41,41E,45), Mjcf,
  • Mjcfe. Series: Fm, Mac50.Fmcfe, Fmcfec, J3F, J65X, Jcfx,
  • Kj3Fc,
  • Pitco Fryer Gas Fryers Which Are Rated @ Over 100,000 Btu.
  • Models:24R, 18Wks, 14F

Description

Pitco P5045651 Fryer Natural Gas Safety Control Valve is used to control the correct amount of natural gas is required safely and effectively. This valve has a 120 VAC actuator as well as 3/4” FPT inlet and outlet and operates safely in the kitchen by closing the gas supply if there is a problem with the valve. It is versatile in that it works well with different fryers, easy to install, and can accommodate up to 300,000 BTU, which is suitable for high usage cooking. This valve is essential to control the fryer effectively and to cook food safely at the same time.

Dimensions:

  • Weight: 2.4 lbs
  • Length: 5.75 in
  • Height: 3.5 in
  • Width: 4.5 in

Step1: Shut off main gas supply and disconnect electrical power before starting installation.

Step2: Remove old fryer valve assembly and thoroughly clean inlet/outlet threads.

Step3: Apply approved gas-rated sealant and securely mount the new valve correctly.

Step4: Connect 3/4" FPT inlet/outlet lines securely; avoid over-tightening fittings.

Step5: Wire 120 VAC actuator according to manufacturer wiring diagram.

Step6: Restore gas supply, check for leaks using approved solution, and test operation safely.

  • What maintenance is required for the Pitco P5045651 Safety Control Valve?

    Inspect the fryer valve for gas leaks, corrosion, and secure connections during routine service. Verify proper actuator operation and ensure smooth valve response. Clean surrounding components and ensure gas pressure remains within specified limits to maintain better operation.

  • What are common issues with the Pitco P5045651 Safety Control Valve?

    • Valve failing to open or close properly.
    • Actuator not receiving or responding to power.
    • Fryer gas leakage at inlet or outlet fittings.
    • Inconsistent gas flow causing burner performance issues.

Customer Reviews

No reviews yet. Be the first to write one!