The Vulcan Hart 00-414146-00002 Fryer High Limit Thermostat Manual Reset is a safety temperature control component used in commercial systems to prevent overheating, during operation. It monitors soil level and automatically interrupts the heating circuit if it excee‌ds its fixed high-limit setting typically‍ around 435°F. Inst‌alled within the control and sensing assembly it includes a manual reset feature that requires user intervention before the unit can resume operation after a shutdown event. It commonly used in restaurant and kitchen equipment, it works as a vital safety part within‌ the temperature protection system

Dimensions

  • Length: 6.5 In
  • Width: 5 In
  • Height: 3 In
  • Weight: 0.7 lbs
https://partsfe.com/media/catalog/product/v/u/vulcan-hart-00-414146-00002-fryer-hi-limit-thermostat-w-manual-reset-55807.jpg

Product Notes

  • [ Hi-Limit Type - Lch W/Manual Reset ] [ Temp 435 Fixed ]
  • [ Bulb 1/4" X 4-7/8" Nickel ][ Cap 24" ] [ Brkt 13 ]
  • Vulcan Fryer 2Nd Hi-Limit For Series:
  • Eef-M/Sm, Ref-M/Sm, Spe, Sper.

Used to regulate safety temperature limits in commercial fryer systems, this high limit thermostat helps protect equipment from overheating by interrupting operation when temperatures reach its fixed 435°F limit. This manual reset control includes a 1/4" x 4-7/8" nickel bulb and a 24" capillary tube that monitors fryer temperatures and activates the safety cutoff when excessive heat conditions occur. Commonly used as a secondary high-limit safety control in commercial fryers, it plays an important role in maintaining safe equipment operation. If a damaged or malfunctioning high-limit thermostat fails to respond properly to excessive temperatures, replacing it may help restore critical over-temperature protection and support stable fryer performance.

Equipment Compatibility:
Designed for fryer temperature safety control applications, the Vulcan Hart High Limit Thermostat includes compatible commercial fryers used in electric fryer and deep fryer applications. This High Limit Thermostat 00-414146-00002 is compatible with commercial equipment from leading brands such as Vulcan Hart and Hobart, and more, where over-temperature protection is required for proper equipment operation.

Brand Compatibility:
This high-limit thermostat replaces multiple part numbers used across compatible equipment models from brands such as Vulcan Hart and Hobart. Complete cross-reference details are provided separately for identification and ordering purposes.

Product Specifications:
SKU: 00-414146-00002
Manufacturer: Vulcan Hart
Product Type: High Limit Thermostat
Reset Type: Manual Reset
Fixed Temperature Rating: 435°F
Bulb Size: 1/4" x 4-7/8"
Bulb Material: Nickel
Capillary Length: 24"
Application: Commercial Fryer Safety Control

Key Features:

  • Provides secondary over-temperature protection for commercial fryer systems by helping interrupt operation when unsafe temperature conditions occur
  • Manual reset configuration allows the fryer to be restarted only after the issue has been addressed, and the control has been reset
  • Fixed 435°F temperature limit for reliable high-temperature safety monitoring
  • 1/4" x 4-7/8" nickel sensing bulb designed to accurately detect fryer oil temperature conditions
  • 24" capillary length supports installation within compatible fryer control assemblies
  • Used in commercial fryer safety control applications where overheat protection is required for proper equipment operation

Technician Feedback:

“The fryer's high-limit control responded more consistently after replacement.”

Write Your Own Review
You're reviewing:Vulcan Hart 00-414146-00002 Fryer High Limit Thermostat Manual Reset
Your Rating
Customer Questions
What maintenance is required for the Vulcan Hart 00-414146-00002 High Limit Thermostat?

Inspect the high limit thermostat regularly for dust, debris, or corrosion. Test its functionality periodically to ensure accurate temperature cutoff. Keep wiring secure and free from damage. Proper maintenance prevents overheating and ensures stable fryer operation.

What are the common issues with the Vulcan Hart 00-414146-00002 High Limit Thermostat?

  • Inaccurate temperature sensing.
  • Frequent tripping or false shutdowns.
  • Wiring or connection faults.
  • Failure to reset after overheating.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off the fryer and unplug it from the power source.

Step2: Remove any covers or panels to access the thermostat location.

Step3: Unscrew and gently detach the old high-limit thermostat.

Step4: Check the mounting area for dirt or corrosion and clean it if necessary.

Step5: Position the new thermostat in the same orientation.

Step6: Secure it with screws and ensure it is stable.

Step7: Reconnect all wiring according to the original configuration.