Step1: Disconnect power supply and allow the steamer to cool completely before servicing.
Step2: Remove the access panel and locate the existing blower motor assembly.
Step3: Disconnect wiring and mounting screws, then carefully remove the old motor and fan.
Step4: Position the new blower motor kit and secure it with original mounting hardware.
Step5: Reconnect wiring according to the unit’s diagram and replace the access panel.
Step6: Restore power and test the steamer to confirm proper blower operation.