Southbend 1164076 Range Blower W/ Plate Flange 4-1/2" X 4-1/2" DIA CCW

Special Price $663.47 Regular Price $1,293.32
In stock
SKU
1164076
The Southbend 1164076 Range Blower is a kitchen equipment with a plate flange of 4-1/2” X 4-1/2” DIA CCW and is creates a superior venting and air circulation regime while cooking food. This blower works through effectively expelling smoke, steam and odors making the cooking environment cleaner. Being high built and easy to fit it is ideal for any type of commercial kitchen environment. These are the benefits of the new design such as better air quality, low temperatures, and health standards compliance.

Dimensions

  • Length: 5.5 In
  • Width: 5.7 In
  • Height: 5.7 In
  • Weight: 4.1 lbs
https://partsfe.com/media/catalog/product/s/o/southbend-1164076-range-blower-w-plate-flange-4-1-2-x-4-1-2-dia-ccw-94821-2.jpg

Product Notes

  • 115V Blower, Fasco, 4-1/2" X 4-1/2" Plate Welded On Flange
  • 1-7/16" X 4-3/32" Mount Ctrs, Looking At Frame- Ccw, Air To
  • You, Has Wire Leads,
  • Southbend
  • Broiler Infrared Units With D Suffix, 171-40 A/C/D
BLODGETT:
-Z1164095, Z1164095
SOUTHBEND:
-1164076, -1164095, 1164076, 1164095
Write Your Own Review
You're reviewing:Southbend 1164076 Range Blower W/ Plate Flange 4-1/2" X 4-1/2" DIA CCW
Your Rating
Customer Questions
What maintenance is required for the Southbend 1164076 Blower W/ Plate Flange?

For maintenance, regularly inspect the range blower assembly for dust buildup and clean the wheel and housing to ensure smooth airflow. Tighten mounting bolts and check flange alignment to prevent vibration. Lubricate motor bearings if applicable and verify electrical connections.

What are common issues with the Southbend 1164076 Blower W/ Plate Flange?

  • Reduced airflow due to clogged blower wheel or debris accumulation.
  • Excess vibration from loose mounting or imbalanced wheel.
  • Motor overheating or intermittent operation from electrical faults or worn components.
  • Noise during operation caused by bearing wear or misalignment.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power and gas supply, and ensure equipment is fully cooled; wear gloves for safety.

Step2: Remove access panel and detach existing blower assembly carefully.

Step3: Position new blower with plate flange, align mounting holes, and secure screws tightly.

Step4: Reconnect wiring according to manufacturer diagram, confirming correct CCW rotation direction.

Step5: Reinstall cover, restore power, and test operation for proper airflow and vibration.