APW 46910700 High-Limit Thermostat 235°F 15A 120V

Special Price $17.86 Regular Price $28.33
In stock
SKU
46910700
Manufacturer:
The APW 46910700 High-Limit Thermostat is a temperature safety control that is used to cut off electrical power when the internal temperature rises beyond 235°F. It is rated 15 amps at 120 volts and assists in avoiding overheating conditions of commercial warming and cooking equipment. This thermostat is installed in the control circuit of the appliance, and it measures the internal temperatures and closes the circuit when the limits are exceeded for safe operation. It acts as a protective component in the entire heating system, which is usually applied in food service equipment.

Dimensions

  • Length: 2.125 In
  • Width: 1.125 In
  • Height: 0.5 In
  • Weight: 0.04 lbs
https://partsfe.com/media/catalog/product/a/p/apw-46910700-hi-limit-235f-444-38-15a-120v-64097-2.jpg

Product Notes

  • Hi-Limit, Temp 235 F Fixed,
  • American Permanent Ware
  • Steamer Hot Dog Steamer: Ds-1A S/N 9207001 & Above.
APW WYOTT:
Write Your Own Review
You're reviewing:APW 46910700 High-Limit Thermostat 235°F 15A 120V
Your Rating
Customer Questions
What maintenance is required for the Apw 46910700 High-Limit Thermostat?

Regularly inspect the thermostat for secure mounting, proper wiring connections, and signs of heat damage. Test the high-limit function periodically to ensure it interrupts power during overheating conditions. Keep surrounding components clean and free from grease buildup, and disconnect electrical power before performing any service or inspection work.

What are common issues with the Apw 46910700 High-Limit Thermostat?

  • Frequent false tripping during normal operation.
  • Failure to trip when overheating occurs.
  • Open circuit preventing equipment from heating.
  • Loose or damaged electrical terminals.
  • Inaccurate temperature sensing causing shutdowns.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power supply to prevent shock.

Step2: Remove access panel and locate old hi-limit thermostat.

Step3: Disconnect wiring, noting terminal positions.

Step4: Mount in same position and secure.

Step5: Reconnect new thermostat wires firmly to matching terminals.

Step6: Restore power and test for proper reset at temperature.

Step7: Ensure unit cycles off at limit and check safe operation.