U-Line 5300-645 Thermostat KX, 3/8 X 5-3/8, 60

Special Price $391.40 Regular Price $613.47
In stock
SKU
5300-645
Manufacturer:

Dimensions

  • Length: 6 In
  • Width: 1.5 In
  • Height: 2.5 In
  • Weight: 0.75 lbs
https://partsfe.com/media/catalog/product/u/-/u-line-5300-645-thermostat-kx-3-8-x-5-3-8-60-1.jpg

Product Notes

  • Type - Kx Temp 250-375 Bulb 3/8" X 5-3/8"
  • Cap 60" Mount 11
  • Dial # 22-1027 Black T'Stat Knob W/ White Printed Numbers,
  • 2-1/4" Dia Off-400-200 Mount .187" Flat Down
  • Lang Black & Silver T'Stat Knob # 22-1516,
  • Off-400-200, 2" Dia, .187" D-Stem, Flat Down.
  • Lang Fryer C-28, C-28M.
  • Pitco Fryer All Electric Fryers.
  • Em14 & Em14Dl & Em40 & Em40Dl(S/N
  • 1450521 & Up).
  • Super-Chef Fryer El-14C (Old El-6 & Fel-14), El-14Fm (Old
  • Fel-10.8), El-414 , El-914 (Old El-4.8)
Write Your Own Review
You're reviewing:U-Line 5300-645 Thermostat KX, 3/8 X 5-3/8, 60
Your Rating
Customer Questions
What maintenance is required for the U-Line 5300-645 Thermostat?

Inspect thermostat sensing bulb and capillary tube for bends, kinks, or damage regularly. Ensure electrical connections remain tight and free of corrosion. Keep surrounding area clean and free from moisture buildup. Proper calibration checks help maintain accurate temperature control and prevent inconsistent cooling performance.

What are common issues with the U-Line 5300-645 Thermostat?

  • Inaccurate temperature regulation or drift.
  • Failure to cycle compressor on or off.
  • Damaged or kinked capillary tube.
  • Loose or corroded electrical connections.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power supply and unplug unit; verify no current flow.

Step2: Remove access panel to reach thermostat compartment.

Step3: Note wiring configuration before detaching old thermostat carefully.

Step4: Disconnect wires and remove faulty unit carefully.

Step5: Install new thermostat KX in same position securely.

Step6: Reconnect wiring securely as per diagram instructions.

Step7: Reassemble panel, restore power, test operation, ensure proper grounding and safety before use.