Star Mfg 2V-Y8832 Charbroiler Burner Control Manual Valve

Special Price $47.49 Regular Price $64.92
In stock
SKU
2V-Y8832
Griddle & Grill Parts,
Manufacturer:
The Star Mfg 2V-Y8832 Charbroiler Burner Control is used to regulate the amount of gas that flows to the assembly in compatible commercial appliance. It works with a manual control system which regulates gas flow to aid in the ignition and control of the burner flame during cooking. It is used in the gas control section of certain charbroiler models and is used in conjunction with the burner and fuel supply system to regulate heat output. It is frequently applied in restaurant kitchen preparing station and other commercial, food service setting, where gas-powered cooking equipment is used regularly for routine food preparation.

Dimensions

  • Weight: 0.313 lbs
https://partsfe.com/media/catalog/product/b/u/burner-valve-for-star-mfg-part-2v-y8832-24739-2.jpg
Manufacturer Name: Star Mfg
Product Number: 2V-Y8832
OEM Part Number: 2V-Y8832
Product Description: Gas In 1/8" Npt, Gas Out 3/8"-27, #46 Hood Orifice & Point,;Adjustable, Stem 1-3/4" Long, Flat Down, On/Off,;For Lp Hood Orifice Use # 26-1080;Garland Range 40-(4,6,7), 43-(40,43,50,53),;44-(40,43,50,53), 45-40, 46-40R, 46-50, 47-(40,50).;Montague Broiler Series: Uf, Ufs, Ufsc, Ufsm (After 10/91).;Grill 2436, 2436T, 2472, 2472T.;Oven 28Cbsf.;Range 2020S, Cr1-10, Sp2020. Series: 136, V136.;Star Broiler, Grill;Hot Plate/Range 601Spr, 602, 602H, 804H
Similar Models:1046296 - Garland, G4447-47A - Garland, G4447-47F - Garland, G4447-50F - Garland, G4447-51F - Garland, G4447-55F - Garland, G4447-57F - Garland, G4447-61F - Garland, G4447-63F - Garland, 01001-4 - Montague
Dimensions:
Length:4in/10.16cm
Width:0.75in/1.9cm
Height:1.25in/3.18cm
Weight:0.19lbs/86.18g

Choose the best Commercial kitchen & Restaurant equipment parts and supplies from PartsFe!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at 866-863-0907 or contact@partsfe.com

STAR MFG:
Write Your Own Review
You're reviewing:Star Mfg 2V-Y8832 Charbroiler Burner Control Manual Valve
Your Rating
Customer Questions
What is the Best Electric Griddle?

Electric Griddle is an electronic equipment that uses an electric element as its heat source. It has a large cooking surface often made up of nonstick material. Electric Griddle has a surface which you do not find in the regular stovetop cookware. ...

What maintenance is required for the Star Mfg 2v-Y8832 Burner Valve?

Regularly inspect the burner valve for gas leaks, corrosion, or debris that may affect gas flow. Ensure connections remain tight and clean to prevent pressure loss. Operate the valve smoothly to avoid internal sticking. Always shut off gas supply before servicing.

What are common issues with the Star Mfg 2v-Y8832 Burner Valve?

  • Gas flow restriction due to internal blockage.
  • Valve knob becoming stiff or difficult to turn.
  • Leaks developing around connection points.
  • Inconsistent flame control or fluctuating burner output.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas supply and disconnect power to the appliance.

Step2: Remove access panel to reach the existing burner valve.

Step3: Disconnect gas line and control knob from the old valve.

Step4: Unscrew and remove the faulty valve carefully.

Step5: Install the new valve and secure it firmly.

Step6: Reconnect gas line and control knob.