Step1: Disconnect power completely and check the appliance is fully de-energized before opening the unit.
Step2: Remove the control panel and locate the existing thermostat and capillary routing path.
Step3: Carefully detach the old thermostat, including bulb and wiring connections, noting positions for reference.
Step4: Install the new thermostat and secure the sensing bulb in the proper heat zone.
Step5: Route the cable away from sharp edges and hot surfaces, then connect terminals securely.
Step6: Restore power and test temperature control to confirm accurate cycling and better operation.