Pitco PTP5047583 Thermostat GS, 3/8 X 4-1/2, 60

Special Price $202.00 Regular Price $311.25
In stock
SKU
PTP5047583
Thermostat Gs, 3/8 X 4-1/2, 60

Dimensions

  • Length: 5.5 In
  • Width: 4.5 In
  • Height: 2.5 In
  • Weight: 1 lbs
https://partsfe.com/media/catalog/product/p/i/pitco-ptp5047583-thermostat-gs-3-8-x-4-1-2-60-18098.jpg

Product Notes

  • [ Type - Gs ] [ Temp 60-250F ] [ Bulb 3/8" X 4-1/2" ]
  • [ 3/8" Stuff Box ] [ Cap 60" ] [ Gas In/Out 3/8" Fpt ]
  • [ Use Dial # 22-1003 Off-250-60 W/ 4 Way Mount ]
  • Pitco Warmer
MAGIKITCH'N:
U-LINE:
4290-008, GS-C8-060-14, GSC80600000
Write Your Own Review
You're reviewing:Pitco PTP5047583 Thermostat GS, 3/8 X 4-1/2, 60
Your Rating
Customer Questions
What maintenance is required for the Pitco PTP5047583 Thermostat?

Inspect the thermostat sensing bulb and capillary for damage, bends, or grease buildup that may affect accuracy. Clean surrounding fryer areas to prevent residue interference. Check calibration periodically and ensure all connections are secure for stable temperature control and safe fryer operation.

What are common issues with the Pitco PTP5047583 Thermostat?

  • Inconsistent fryer temperatures due to faulty sensing bulb.
  • Delayed heating response from capillary tube damage.
  • Thermostat failure causing overheating or underheating.
  • Grease contamination affecting sensor accuracy.
  • Loose wiring or connections leading to erratic operation.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect appliance from power/gas and allow to cool completely for safety, ensure unit is isolated.

Step2: Remove access panel and locate the existing thermostat assembly for servicing.

Step3: Disconnect wiring terminals carefully, noting positions before removal.

Step4: Unscrew and remove old thermostat from mounting bracket and housing.

Step5: Install new thermostat, secure mounting, and reconnect wires to matching terminals securely.

Step6: Reassemble panel, restore power, and test temperature calibration, verify operation.