Star Mfg C9-3B82D0181 Warmer Indicator Light Red 5/16" Hole 250V

$10.14
In stock
SKU
C9-3B82D0181
The Star Mfg C9-3B82D0181 Indicator Light Red works by switching on when electrical current is applied to pass through the internal element to indicate that the control circuit of the warmer is active. The light is low power consuming to be on when connected to the wiring of the equipment. It is attached to the front panel of warmers or buffet units, where it fits into a 5/16" hole. This red indicator is intended to run at 250 volts and can be regarded as a visible sign of the presence of electricity without interfering with the usual functioning of the warmer in service.

Dimensions

  • Length: 11 In
  • Width: 0.5 In
  • Height: 0.5 In
  • Weight: 0.1 lbs
https://partsfe.com/media/catalog/product/s/t/star-mfg-c9-3b82d0181-250v-red-indicator-light-fits-5-16-hole-63434-2.jpg

Product Notes

  • 250 V [ Fits Hole 5/16" ] [10" Leads ] [Color Red]
  • [ Type Hat Flat ][ Bezel White]
  • Fastener Clip # 26-2263 Not Included.
  • Cleveland
  • Hobart Warmer, Fryer Ck91, Ck93
  • Lang Broilers: Ggb-(24Ti,36Ti,48Ti).
  • Cheesemelters: 0-2-10-(3,4,5,Including Chill'S
  • Models), mm-(2,3,4,24,36,48).
  • Fryer C-28, C-28M, C-40.
  • Grill G-(3E,4E,5E,6E,3Ei,4Ei,5Ei,6Ei(All With S/N E51388
  • To E89816 & Beg With F89817)), G-(24Ti,36Ti,48Ti,60Ti,
  • 72Ti), Gc-(24T,24Ti,36T,36Ti,48T,48Ti,60T,60Ti,72T,
  • 72Ti), Lg-(24,36,48,60,72(Excluding 380V Models)),
  • Lg-(24S,36S,48S,60S,72S), Lgr-48, Sxl-(24,36,48,60,
  • 72), Usa 24-6, Xl-(24,36,48,60,72).
BLOOMFIELD:
CLEVELAND:
GENERAL ELECTRIC:
HOBART:
00-342347-00001, 342347-1, XNC25X78/342347-1
MARKET FORGE:
MIDDLEBY MARSHALL:
Write Your Own Review
You're reviewing:Star Mfg C9-3B82D0181 Warmer Indicator Light Red 5/16" Hole 250V
Your Rating
Customer Questions
What maintenance is required for the Star Mfg C9-3B82D0181 Indicator Light?

Keep terminals clean and ensure wiring is securely fastened to prevent intermittent contact. Periodically wipe the lens to maintain visibility and inspect for heat damage. Verify correct voltage operation and replace if flickering or dimming occurs.

What are common issues with the Star Mfg C9-3B82D0181 Indicator Light?

  • Loose terminal connections are causing intermittent illumination.
  • Flickering or dim output under voltage fluctuations.
  • Overheating of housing during extended use.
  • Moisture ingress leading to internal corrosion or failure.
  • LED degradation over time causes reduced brightness.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off power and check circuit is de-energized.

Step2: Insert indicator light into panel hole and secure mounting nut firmly.

Step3: Connect leads to correct terminals per wiring diagram provided.

Step4: Tighten all connections and ensure insulation is properly seated.

Step5: Restore power and test indicator light operation.

Step6: Check for secure fit, correct illumination, and safe operation.