Turbochef TBCNGC1140 Thermocouple
Dimensions
- Length: 5 In
- Width: 4.5 In
- Height: 1 In
- Weight: 0.04 lbs
Product Notes
- Thermocouple
- Turbochef Convection Oven: Hhb,
- Convection & Microwave Oven: Ngc, Ngc2
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Step1: Disconnect power and allow oven to cool completely,apply lockout/tagout.
Step2: Remove access panel to place existing thermocouple near heating area.
Step3: Note wiring route and connection points for reference.
Step4: Disconnect thermocouple leads from control board or terminal block.
Step5: Remove mounting clip or screw securing old probe.
Step6: Install new thermocouple in same position, ensuring proper heat zone placement.
Step7: Reconnect wires securely and reinstall panel.
Step8: Restore power and check temperature reading accuracy.